NOTE!
For a secure seal, apply thread sealant to the fitting threads, according to the maker's
instructions. Do Not use Teflon tape as a thread sealer, as small particles of the tape may
break off and block the small air passages in the torch. Connect as follows:
Installing Optional Two - Stage Air Filter Kit
This optional two - stage air line filter is also for use on compressed air shop systems. Filter removes moisture and
contaminants to at least 5 microns.
Connect the air supply as follows:
1. Attach the Two Stage Filter bracket to the back of the power supply per instructions supplied with the filter
assembly.
Manual 0-5398
Hose Clamp
Gas Supply
Hose
Optional Single - Stage Filter Installation
INSTALLATION
ESAB CUTMASTER 120
Regulator/Filter
Assembly
Inlet Port
Art # A-07944
1/4 NPT to 1/4"
(6mm) Fitting
3-3