General Description; Operation; Setup; Preparing To Paint - Titan Performer 640i Notice D'utilisation

Masquer les pouces Voir aussi pour Performer 640i:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

General Description

This airless sprayer is a precision power tool used for spraying
many types of materials. Read and follow this instruction
manual carefully for proper operating instructions,
maintenance, and safety information.
Pressure Control
Knob
ON/OFF
Switch
Outlet Fitting
PRIME/SPRAY
Valve
Return
Hose
Siphon
Tube

Operation

WARNING
This equipment produces a fluid stream at extremely high
pressure. Read and understand the warnings in the
Safety Precautions section at the front of this manual
before operating this equipment.

Setup

Perform the following procedure before plugging in the power
cord of an electric unit.
1. Ensure that the siphon tube and the return tube are
attached and secure.
2. Attach a minimum of 50' of nylon airless spray hose to the
unit.
3. Attach an airless spray gun to the spray hose. Do not
attach the tip to the spray gun yet. Remove the tip if it is
already attached.
WARNING
Make sure all airless hoses and spray guns are electrically
grounded and rated for at least 3200 psi (220 bar) fluid
pressure.
4. Make sure the pressure control knob is in its OFF position
in the black zone.
5. Make sure the ON/OFF switch is in its OFF position.
6. Fill the wet cup with one tablespoon of piston seal
lubricant (Piston Lube).
CAUTION
Never operate unit for more than ten seconds without
fluid. Operating this unit without fluid will cause
unnecessary wear to the packings.
7. Make sure the electrical service is 120V, 15 amp minimum.
8. Plug the power cord into a properly grounded outlet at
least 25' from the spray area.
CAUTION
Always use a minimum 12 gauge, three-wire extension cord
with a grounded plug. Never remove the third prong or use
an adapter.
English
Preparing a New Sprayer
If this unit is new, it is shipped with test fluid in the fluid section
to prevent corrosion during shipment and storage. This fluid
must be thoroughly cleaned out of the system with mineral
spirits before you begin spraying.
Always keep the trigger lock on the spray gun in the
locked position while preparing the system.
Motor
1. Place the siphon tube into a container of mineral spirits.
2. Place the return tube into a metal waste container.
3. Set the pressure to minimum by turning the pressure
control knob to the "Min" setting in the yellow zone.
Tool
Box
Min. – 1800 PSI
(yellow zone)
OFF
Filter
(black zone)
PulseClean
(red zone)
OFF
(black zone)
4. Move the PRIME/SPRAY valve down to the PRIME
position.
5. Turn the unit on by moving the ON/OFF switch to the ON
position.
6. Allow the sprayer to run for 15–30 seconds to flush the
test fluid out through the return tube and into the waste
container.
7. Turn the unit off by moving the ON/OFF switch to the OFF
position.

Preparing to Paint

Before painting, it is important to make sure that the fluid in the
system is compatible with the paint that is going to be used.
NOTE: Incompatible fluids and paint may cause the
valves to become stuck closed, which would
require disassembly and cleaning of the
sprayer's fluid section.
Always keep the trigger lock on the spray gun in the
locked position while preparing the system.
1. Place the siphon tube into a container of the appropriate
solvent. Examples of the appropriate solvent are water for
latex paint or mineral spirits for oil-based paints.
2. Place the return tube into a metal waste container.
3. Set the pressure to minimum by turning
the pressure control knob to the "Min"
setting in the yellow zone.
4. Move the PRIME/SPRAY valve down to
the PRIME position.
5. Turn the unit on by moving the ON/OFF
switch to the ON position.
6. Allow the sprayer to run for 15–30 seconds to flush the old
solvent out through the return tube and into the metal
waste container.
7. Turn the unit off by moving the ON/OFF switch to the OFF
position.
NOTE: Make sure that the spray gun does not have a
tip or tip guard installed.
8. Move the PRIME/SPRAY valve up to the SPRAY position.
9. Turn the unit on.
4
CAUTION
Min.
PSI
1800 – 3200 PSI
(green zone)
Max.
PSI
Pressure Control Knob
CAUTION
Min.
PSI
© Titan Tool Inc. All rights reserved.
Max.
PSI

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

786-3000

Table des Matières