Painting; Electronic Pressure Control Indicators - Titan Performer 640i Notice D'utilisation

Masquer les pouces Voir aussi pour Performer 640i:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10. Unlock the gun by turning the gun trigger lock to the
unlocked position.
WARNING
Ground the gun by holding it against the
edge of the metal container while flushing.
Failure to do so may lead to a static
electric discharge, which may cause a fire.
11. Trigger the gun into the metal waste
container until the old solvent is gone and
fresh solvent is coming out of the gun.
12. Lock the gun by turning the gun trigger
lock to the locked position.
13. Set down the gun and increase the
pressure by turning the pressure control
knob slowly clockwise into the green
zone.
14. Check the entire system for leaks. If
leaks occur, follow the "Pressure Relief Procedure" in this
manual before tightening any fittings or hoses.
15. Follow the "Pressure Relief Procedure" in this manual
before changing from solvent to paint.
WARNING
Be sure to follow the pressure relief procedure when
shutting the unit down for any purpose, including
servicing or adjusting any part of the spray system,
changing or cleaning spray tips, or preparing for cleanup.

Painting

1. Place the siphon tube into a container of paint.
2. Place the return tube into a metal waste container.
3. Set the pressure to minimum by turning
the pressure control knob to the "Min"
setting in the yellow zone.
4. Move the PRIME/SPRAY valve down to
the PRIME position.
5. Turn the unit on by moving the ON/OFF
switch to the ON position.
6. Allow the sprayer to run until paint is coming through the
return tube into the metal waste container.
7. Turn the unit off by moving the ON/OFF switch to the OFF
position.
8. Remove the return tube from the waste container and
place it in its operating position above the container of
paint.
9. Move the PRIME/SPRAY valve up to the SPRAY position.
10. Turn the unit on.
11. Unlock the gun by turning the gun trigger lock to the
unlocked position.
WARNING
Ground the gun by holding it against the
edge of the metal container while flushing.
Failure to do so may lead to a static
electric discharge, which may cause a fire.
12. Trigger the gun into the metal waste
container until all air and solvent is
flushed from the spray hose and paint is flowing freely.
from the gun.
13. Lock the gun by turning the gun trigger
lock to the locked position.
14. Turn the unit off.
15. Attach tip guard and tip to the gun as
instructed by the tip guard or tip
manuals.
© Titan Tool Inc. All rights reserved.
POSSIBLE INJECTION HAZARD. Do not spray without the
tip guard in place. Never trigger the gun unless the tip is in
either the spray or the unclog position. Always engage the
gun trigger lock before removing, replacing or cleaning tip.
16. Turn the unit on.
17. Increase the pressure by turning the pressure control knob
slowly clockwise toward the green zone and test the spray
pattern on a piece of cardboard. Adjust the pressure control
knob until the spray from the gun is completely atomized.
NOTE: Turning the pressure up higher then needed to

Electronic Pressure Control Indicators

Trigger lock in
The following is a description of the indicators on the electronic
locked position.
pressure control.
Blinking Yellow =
0 PSI – priming pressure
Solid Yellow =
priming pressure – 1800 PSI
Solid Green =
1800 PSI – 3200 PSI
Pressure Indicator
The pressure indicator shows the current operating pressure of
the sprayer. It has three different indications: blinking yellow,
solid yellow, and solid green.
Min.
PSI
Blinking Yellow
When the pressure indicator is blinking yellow, the sprayer is
Max.
operating between 0 and 200 PSI. A blinking yellow pressure
PSI
indicator means:
• The sprayer is plugged in and turned "ON"
• The sprayer is at priming pressure (little or no pressure)
• It is safe to move the PRIME/SPRAY valve between
positions
• It is safe to change or replace the spray tip
NOTE: If the pressure indicator begins blinking yellow
Solid Yellow
When the pressure indicator is solid yellow, the sprayer is
operating between 200 and 1800 PSI. A solid yellow pressure
indicator means:
• The sprayer is at the proper pressure setting for spraying
stain, lacquer, varnish, and multi-colors
• If the pressure indicator goes to solid yellow when the
pressure is set so that it starts at solid green, it indicates
one of the following:
a. Tip Wear Indicator — when spraying with latex or at
high pressure the solid yellow appears. This means
the tip is worn and needs to be replaced.
b. Tip Too Large — when a tip that is too large for the
sprayer is put in the gun, the pressure indicator will turn
from solid green to solid yellow.
c. Fluid Section Wear — if a solid yellow pressure
indicator appears when using a new tip and the
Trigger lock in
pressure is set at maximum, service may be required
locked position.
(worn packings, worn piston, stuck valve, etc...).
5
WARNING
atomize the paint will cause premature tip wear
and additional overspray.
Pressure
Indicator
Motor Running Indicator
Programmer Port
Programmer Port
Dust Cover
when the pressure control knob is set at a
higher pressure and the PRIME/SPRAY valve is
in the SPRAY position, either the spray tip is
worn or the sprayer is in need of service/repair.
English
Circuit
Breaker

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

786-3000