TIMED NEGATIVE CHILLING AND STORAGE CYCLE
To start the cycle:
ensure the device is in "stand-by" mode and no procedures are running
press
to select "nEg" and ensure the LED
press
within 15 seconds: the display will show the duration of the blast chilling step (in
minutes)
press
or
cycle is selected, when the value assigned by parameter r2 is restored)
press
:
During chilling:
the display shows the residual chilling time remaining
the LED
is on
parameter r2 sets the chilling time duration
parameter r8 sets the operational setpoint
press
several times to:
- display the message "nEg"
- display the cabinet temperature
- exit the procedure, or leave for 15 s.
Once the chilling period has elapsed:
the device switches to storage mode
the display shows the message "End"
the buzzer sounds for the period of time set by parameter AA
press any key to mute the buzzer; press once more to cancel the message "End".
During storage:
the display shows the cabinet temperature
the LEDs
and
the parameter rA sets the operational setpoint
press
several times to:
- display the message "nEg"
- display exit the procedure or leave for 15 seconds
To interrupt the cycle:
press
for 2 seconds.
within 15 seconds to change the value (the setting remains active until another
after 2 minutes , run timed negative chilling and storage cycle
are on
is flashing