Installation
The range hood should be installed directly above the stove. In order to ensure the safety and the best effect of oil
fume suction, it is suggested that the minimum distance between the top of the range hood and the cooker supporting
surface on the stove should be 29
state or region has laws on installation height of the range hood, please comply with the laws, but the fume suction
effect of the product may be greatly affected.The installation of the range hood can be divided into three installation
modes: no upper cabinet, with upper cabinet and upper cabinet with decoration panel.Note:
1. The hitching leg must be fixed to the beam with a screw.
2. Please operate with protective gloves and goggles.
3. The depth of the upper cabinet of the range hood from the wall shall be less than 15"(380mm).
Installation with upper cabinet
1. Open the container and take out the machine, and check the items inside against the packing list.
2. Open the duct hole at the top of the upper cabinet according to the opening position and size as shown in the picture
below.
3. Draw a vertical center line in the installation position, and then use the beam detector to find the beam to fix the
hitching leg, and mark it with a pencil.
4. Determine the installation position of the body hitching leg: confirm the hitching leg position with the lowest point at the
bottom of the upper cabinet plate as the base and mark the drill holes. The relevant size is given as below: the distance
from the bottom of the upper cabinet plate to the center of the area A of the hitching leg hole is
15- /
1
"(395mm)
2
B area
2"
(50mm)
A area
2- /
3
"
8
(60mm)
5.
Drill a hole 2- "(60mm)-2- "(70mm) deep (not too large) at the mark with a drill bit with a diameter of
3
/
8
press the expansion pipe into the hole, and reliably fix the hitching leg with 4×60mm wood screws supplied with the
machine. Use a level ruler to make sure the hitching leg is in a horizontal position.
1.
Note:
The hitching leg must be fixed to the beam with a screw.
2.
The A area hole in the figure must be fixed, and the B area hole corresponding to the wooden column must be
fixed with the screw.
-
9
/
"
(750
mm and the maximum should not be greater than 32- /
)
16
Duct diameter
Wall
Hole diameter
1
Ø6"(Ø153mm)
Ø6- "(Ø165mm)
/
2
3
2- /
"
8
(60mm)
4×60
wood screw
3
/
4
33
Range Hood
1
"
(825
mm If the
2
15- /
3
"(400mm)
4
B
A
5
/
).
"(8mm),
16

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cxw-260-a672

Table des Matières