Programming The Receiver Operating Frequency & High Speed Conditioning Of Fan Control; Important - Emerson PORTLAND CF965BS00 Instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10. Programming the Receiver Operating Frequency
& High Speed Conditioning of Fan Control
-- Important - Read This Section Carefully and Follow
the High Speed Conditioning Instructions Closely --
PROGRAMMING THE RECEIVER
OPERATING FREQUENCY & HIGH SPEED
CONDITIONING OF FAN CONTROL
IMPORTANT: Ceiling fan blades MUST be installed
before high speed conditioning can begin.
10.1
Turn the wall control ON/OFF switch to the "OFF" position.
Restore electricity to the ceiling fan branch circuit at the
circuit breaker or fuse box
Flip the SW605 wall control's ON/OFF switch to "ON"
position.
Within one minute of flipping the switch to "ON", push and
hold the FAN OFF button (
code in the receiver. The ceiling fan lights
(if installed) will blink to indicate the SW605 wall control
code has been paired with the receiver.
IMPORTANT: Immediately after successful pairing, the
ceiling fan will automatically begin high speed
conditioning of the motor. During conditioning, the
electronic motor control software is calculating
speeds for the 2nd through 5th speed settings based
on the blades that were installed on the fan.
) for 3 to 5 seconds to set the
10.2
The fan will run for approximately 2 minutes in the upward
direction then reverse direction to down flow and run an
additional 2 minutes. When conditioning is complete, the
IMPORTANT: Do not interrupt the conditioning until
fan will come to complete stop.
the fan comes to a complete stop in approximately
5 minutes. All functions of the control will be rejected
during conditioning.
10.3
10.4
High speed conditioning is now complete.
If programming is unsuccessful, retry the above
instructions after cycling the SW605 wall control ON/OFF
10.5
switch to restart the 1 minute programming time period.
If still unsuccessful, shut off the electricity at the fuse box or
breaker panel and change the SW605 wall control
frequency (page 16). After changing the frequency
settings, repeat instructions 1 - 5 of this section within one
minute of restoring the electricity.
24