8. Programming the Receiver Operating Frequency

PROGRAMMING THE RECEIVER
OPERATING FREQUENCY
8.1
Turn the Wall Control ON/OFF Switch to the "OFF"
position.
Restore Electricity to the Ceiling Fan Branch Circuit at the
Circuit Breaker or Fuse Box.
Flip the Wall Control's ON/OFF Switch to "ON" position.
Within one minute of flipping the Switch to "ON", push and
hold the FAN OFF Button (
Code in the Receiver. The ceiling fan lights
(if installed) will blink to indicate the Wall Control Code has
been paired with the Receiver.
) for 3 to 5 seconds to set the
8.2
If programming is unsuccessful, retry the Step 8.1
instructions after cycling the Wall Control ON/OFF Switch
to restart the 1 minute programming time period.
8.3
If still unsuccessful, shut off the Electricity at the Fuse Box
or Breaker Panel and change the Wall Control frequency
(Page 15). After changing the Frequency settings, repeat
Step 8.1 within one minute of restoring the Electricity.