Installing The Ceiling Cover On The Fan Motor Housing - Emerson PRO II Serie Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4. Installing the Ceiling Cover on the Fan Motor
Housing
4.1
Remove three motor housing screws (every other
screw as illustrated) from the top of the motor housing
(Figure 6).
Retain the three motor housing screws for future use.
4.2
Position the rubber gasket (supplied in parts bag) on
the motor housing.
The three small holes in the gasket should center over
the holes in the motor housing where the three screws
were previously removed (Figure 7).
The three large holes in the gasket should center over
the three screws still installed in the motor housing.
(For Close-to-the-Ceiling Mounting)
Figure 6
RUBBER GASKET
SMALL HOLES (3)
RUBBER GASKET
LARGE HOLES (3)
Figure 7
8
REMOVE SCREWS (3)
MOTOR
HOUSING
SCREWS (3)
MOTOR
HOUSING
INSTALL
RUBBER
GASKET
RUBBER
GASKET
MOTOR
HOUSING
U.L. Model No.: 42-ANT & 52-ANT

Publicité

Table des Matières
loading

Table des Matières