Check for compliance with provi-
sions stipulated in the German BGV
The operating company of commercially used weld-
ing equipment is obliged to have the appliances
checked in accordance with directive EN 60974-4
at regular intervals appropriate for the frequency
of use. Würth recommends having the appliance
checked every 12 months.
Additional safety checks have to be performed after
modifying or repairing the appliance.
Attention!
Improper checks for compliance with accident
prevention regulations may result in destruction of
the machine. Please contact an authorised Würth
service point for more information on checking the
compliance with accident prevention regulations.
Electromagnetic compatibility (EMC)
This appliance conforms to the current EMC
standards.
Please note:
Welding machines consume so much power that
they may affect public electricity networks. For this
reason the mains supply is subject to requirements
regarding the maximum permissible network
impedance. The maximum permissible mains im-
pedance (Z
) of the interface to the mains grid
max
(mains power supply) is specified in the technical
data. Contact the electricity network operator if
required.
The appliance is intended for welding both
in commercial and industrial environments
(CISPR 11 class A). Using the appliance in an-
other environment (e.g. in a residential area) may
affect electrical equipment in that area.
During start-up, electromagnetic problems may be
caused in:
• Power cables, control lines, signal and telecom-
munication lines in the vicinity of the welding /
cutting appliance
• TV and radio transmitters and receivers
• Computers and other control equipment
• Security equipment in commercial buildings (e.g.
alarm systems)
• Cardiac pacemakers and hearing aids
• Calibrating and measuring equipment
• Appliances with insufficient interference resist-
ance
If any other facility or equipment in the
surrounding area is affected, additional
protective barriers may become necessary.
The surrounding area to be taken into consideration
may extend beyond the boundaries of the prem-
ises. This depends both on the type of the building
and on the other activities performed at the site.
Always observe information and instructions
provided by the manufacturer when operating the
appliance. The company operating the appliance
is responsible for the setup and the operation of the
appliance.
If electromagnetic disturbances occur, the operating
company is responsible for the elimination of this dis-
tubances (with technical help from the manufacturer if
necessary).
Product features (Fig. I)
1 Detachable handle
2 Displays/control elements
3 Negative connection socket
4 Positive connection socket
5 Main switch
6 Mains lead connection
7 Air outlet
Technical Data
Art.
IP code
Class of insulation
Cooling type
Labelling
Dimension (LxWxH) in mm
Weight
Mains ratings
Mains voltage
Frequency
Positive mains tolerance
Negative mains tolerance
Power cord
Mains plug
Current consumption I
(100%)
1
Current consumption I
(60%)
1
Current consumption I
(max. current)
1
Mains fuse
Power factor I
2 max
5952 000 160
IP 23 S
F
F
CE, S
337 x 130 x 211
5.25 kg
230 V AC
50-60 Hz
15%
-40%
3 x 2.5 mm²
CEE 16 A
8.1 A
10.5 A
14.5 A
16 A
0.99 cos ϕ