G
B
closing, depending on the structure of the gate, or if there is any light friction that could
compromise the correct working of the system. The low speed is activated (DIP7 OFF)
when the gate leaf is 0.50-0.60 meters away from the complete close or open position.
LED WARNING
DL1 - programming activated (red)
DL2 - radio code programming (green) (only for CRX)
DL3 - gate opening M2 (green)
DL4 - gate closing M2 (red)
DL5 - gate opening M1 (green)
DL6 - gate closing M1 (red)
DL7 - photocell contact (NC) (red)
DL8 - safety strip contact (NC) (red)
FUSES
F1 T315mA
Accessories protection fuse
F2 5A
Motor protection fuse
POINT C - MOTOR ROTATION DIRECTION CHECK
1 - Unlock the operators with the Manual Release - swing open the leaves about halfway
and lock again the operators.
2 - Turn DIP1 to ON position The red LED DL1 starts blinking.
3 - Press the PROG button and hold it - When GREEN LEDS DL3 and DL5 are on, the
gate leaves are opening (with a phase shift of 2 seconds). Check the leaves swinging
and the opening mechanical stopper position (movement is now performed in "man
present" mode, open-close-open-etc.).
If any of the leaf closes instead of opening, release PROG button, turn off the main
power and reverse the two phase wires (V1/2 and W1/2) of the relevant motor/s.
4 - Press the PROG button and hold it to CLOSE completely the gate. When RED
LEDS DL4 and DL6 are on, the gate leaves are closing (with a phase shift of 4
seconds). Check leaves swinging and the closing mechanical stopper position.
5 - After 3 seconds motor starting and for the next 10 seconds motor working, the torque
controls automatically activated. Set the motor torque by the TORQUE Trimmer/s
which varies the output voltage to the motor/s (turn clockwise to increase the torque).
6 - After other 10 seconds motor working, the low speed controls automatically activated
(DIP7 ON). Set the motor low speed by the LOW SPEED Trimmer to select the gate
leaf low speed in approaching.
7 - Close completely the gate.
8 - Turn DIP1 to OFF position, LED DL1 turns off.
During Point C procedure, safety devices (photocells and safetystrip) are not
active and the remote control cannot operate.
(#) In Point D, Point E and Point F procedures, all the safety devices (photocells and safety
strip) will be active, so they must be properly installed and connected to the control
board. Any changing of the safety devices input state, will stop the Point D, Point E or
Point F procedure that must be repeated from the beginning.
POINT D - PROGRAMMING FOR 2 MOTORS (#)
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, LED DL1 starts blinking
3 - Press PROG. Button, motor M1 opens.
4 - Once reached the open position, let 1 second pass and press the PROG button to
cut out motor M1 (time travel of M1 has now been just stored with this operation).
5 - Motor M2 opens, automatically.
6 - Once reached the open position, let 1 second pass and press the PROG button to
cut out motor M2 (time travel of M2 has now been just stored with this operation).
The gap of time between now (stop of motor M2) and the next pressing of the PROG.
button (see step 7 below) will be then stored as waiting time for Automatic Closing
feature.
7 - Press PROG. button, M2 closes and the Automatic Closing time is stored (see
DIP3 function to enable or disable the Automatic Closing feature). The gap of time
between now (close of motor M2) and the next pressing of the PROG. button (see
step 8 below) will be stored as time delay between motor M2 and motor M1 closing,
during normal operations.
8 - Press the PROG. button, motor M1 closes thus setting the delay time between M2
and M1, as explained in step 7 above.
9 - The LED DL1 will turn OFF, signalling exit from the Point D procedure.
Closing of the gate will be carried out at normal speed and only on approaching total
closing at low speed (depending on the adjustment of LOW SPEED trimmer).
10 - Turn DIP2 to OFF position.
During Point D procedure, the safety devices (photocells and safety strip) are active.
POINT E - PROGRAMMING FOR 1 MOTOR (M1) (#)
ATTENTION: in order to manage one motor only, OPEN JUMPER JP17.
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, the LED DL1 starts blinking
3 - Press PROG. button, the motor M1 opens.
4 - Once reached the open position, let 1 second pass and press the PROG button to
cut out motor M1 (time travel of M1 has now been just stored with this operation).
The gap of time between now (stop of motor M1) and the next pressing of the PROG.
button (see step 5 below) will be then stored as waiting time for Automatic Closing
feature.
5 - Press PROG. button, M1 closes and the Automatic Closing time is stored (see DIP3
function to enable or disable the Automatic Closing feature).
6 - The LED DL1 will turn OFF, indicating exit from the Point E procedure. Closing of the
gate will be carried out at normal speed and only on approaching total closing at low
speed (depending on the adjustment of LOW SPEED trimmer).
7 - Turn DIP2 to OFF position.
During Point E procedure, the safety devices (photocells and safety strip) are active.
POINT F - PROGRAMMING OF PEDESTRIAN OPENING (#)
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, the LED DL1 starts blinking quickly.
3 - Immediately, turn also DIP1 to ON position, the LED DL1 starts blinking slowly.
4 - Press the pedestrian pushbutton PED. BUTT, motor M1 opens
5 - When the motor M1 leaf is opened enough for the pedestrian crossing, press the
pedestrian pushbutton to stop the travel (thus defining the opening stroke of motor
M1). The gap of time between now (stop of motor M1) and the next pressing of
the PROG. button (see point 6 below) will be stored as waiting time for Pedestrian
Automatic Closing feature.
6 - Press the pedestrian pushbutton PED. BUTT, M1 closes and the Pedestrian
Automatic Closing time is stored (see DIP3 function to enable or disable the Automatic
Closing feature).
7 - Turn DIP1 to OFF position.
8 - Turn DIP2 to OFF position.
During Point F procedure, the safety devices (photocells and safety strip) are active.
POINT G - PROGRAMMING RADIO CODES FOR COMPLETE
OPENING
(UP TO 62 CODES - ONLY FOR CRX MODELS)
You can only programme the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each, for 10
seconds.
3 - Press the remote control button (normally channel A) within the 10 seconds
proscribed. If the remote control has been correctly programmed, the DL2 LED (green)
will flash once.
4 - The code programming time resets automatically so that you can programme the
next remote control.
5 - To finish programming, let 10 seconds pass and then press the PROG. button briefly.
The red DL1 LED will stop flashing.
6 - Reposition DIP 1 to OFF and DIP 2 to OFF.
7 - You have completed the procedure
PROCEDURE FOR DELETING ALL RADIO CODES USED ONLY FOR COMPLETE
OPENING
You can only delete the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each, for 10
seconds.
3 - Press and hold the PROG button for 5 seconds. The green DL2 LED will flash twice
to confirm that the stored codes have been deleted.
4 - The red programming DL1 LED remains active and you can programme new codes
as shown above if required.
5 - Reposition DIP 1 to OFF and DIP 2 to OFF.
6 - You have completed the procedure.
HOW TO CHECK IF THE MEMORY IS FULL FOR RADIO CODES USED ONLY FOR
COMPLETE OPENING
You can only check the memory if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.
36