Note on optional accessory:
-
Temperature probe (K-type) made of V4A tube
application: insertion probe for soft-plastic materials, liquids, gas and air
measuring range: - 196 °C up to 800 °C
dimensions: length = 210 mm, tube length = 120 mm, tube diameter =
3 mm, V4A (P.no. 044121)
Note on replaceable parts:
-
The BENNING MM 6-2 contains fuses for overload protection:
One fuse rated 11 A rapid-acting (1000 V) 30 kA, D = 10 mm, L = 38 mm
(P.no. 10218772).
-
The BENNING MM 6-1/ MM 6-2 is supplied by means of one integrated 9 V
block battery (IEC 6 LR 61).
-
The above mentioned safety cable (tested spare part) are approved in
accordance with CAT III 1000 V/ CAT IV 600 V and for a current up 10 A.
4.
Description of unit
See fig. 1:
The display and operating elements shown in fig. 1 are as follows:
Digital display, for the measurement reading, bar graph and display for
overrange indication,
Polarity display,
Battery display,
Function key (blue),
RANGE key, switchover between automatic and manual measuring range,
Δ/PEAK key, relative value function and peak value storage
Smart HOLD key,
8 Button (yellow), display illumination,
Rotating switch, for selecting measuring function.
Socket (positive
Hz (BENNING MM 6-2)
COM socket, joint socket for measurement of current, voltage, resistance,
frequency, temperature, capacity, continuity and diode testing,
Socket (positive), for 10-A range, for currents up to 10 A
Protective rubber holster
LED (red) for voltage indicator and continuity test
) The automatic polarity display for DC current and voltage refers to this.
1
5.
General data
5.1 General data on multimeter
5.1.1
The digital display 1 is designed as a 4 digit liquid-crystal indicator with
15 mm digit height and decimal point. The highest value displayed is 6000.
5.1.2
The bar graph display consists of 60 segments.
5.1.3
The polarity indication functions automatically. Only a polarity con-
trary to the socket definition is indicated, as "-".
5.1.4
The range overload will be displayed with "OL" or "-OL" and sometimes
with an acoustic signal.
Attention: no display or warning by complete overload.
5.1.5
The rotary switch 9 is intended for selecting the measuring function.
5.1.6
The "RANGE" key 5 can be used to change over to the manual meas-
uring ranges and to hide "AUTO" on the display at the same time. By
pressing the key for approx. 2 seconds, the automatic range selection is
activated ("AUTO" on the display).
5.1.7
Press the Δ/PEAK key 6 (relative value function) to store the currently
displayed value and to display the difference (offset) between the stored
measured value and the following measured values. Press the Δ/PEAK
key 6 for 2 seconds to switch over to the "PEAK" function (peak value
storage). The "PEAK" function detects and stores the positive and nega-
tive peak/ crest value (> 1 ms) in the mV/ V AC and mA/ A AC function.
Press the key to call up Pmax, Pmin and the currently measured value
(Pmax, Pmin). Press the key for approx. 2 seconds to switch the device
back to normal operating mode.
5.1.8
"Smart HOLD" - storage of measurement reading: When the "Smart HOLD"
key is pressed, the measurement reading is stored in the memory.
The symbol "HOLD" appears in the display 1 at the same time. If the
measured value increases by 50 digit above the saved value the change
in measured value is shown by a blinking display and by a signal tone.
(changes of measured values between AC and DC voltage/ current will
not be recognized).
5.1.9
Press the yellow key 8 to activate the display illumination. The device is
switched off automatically after 2 seconds or by pressing the key again.
5.1.10 The function key (blue) 4 serves to select the secondary function of the
rotary switch position.
02/ 2020