Safety Notes; Scope Of Delivery - Benning MM 6-1 Notice D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
2.

Safety notes

The instrument is built and tested in accordance with
DIN VDE 0411 part 1/EN 61010-1
DIN VDE 0411 part 2-033/EN 61010-2-033
DIN VDE 0411 part 031/EN 61010-031
and has left the factory in perfectly safe technical condition.
To maintain this condition and to ensure safe operation of the multimeter, the
user must observe the notes and warnings given in these instructions at all times.
Improper handling and non-observance of the warnings might involve severe
injuries or danger to life.
WARNING! Be extremely careful when working with bare con-
ductors or main line carrier! Contact with live conductors will
cause an electric shock!
Attention! Magnets might affect the correct functioning of
cardiac pacemakers and implanted defibrillators. As a user of
such medical devices, keep a sufficient distance to the magnet.
The BENNING MM 6-1/ MM 6-2 may be used only in electrical
circuits of over voltage category III with a maximum voltage of
1000 V or of over voltage category IV with a maximum voltage
of 600 V between the conductor and ground.
Only use suitable measuring leads for this. With measurements
within measurement category III or measurement category IV,
the projecting conductive part of a contact tip of the measuring
leads must not be longer than 4 mm.
Prior to carrying out measurements within measurement cat-
egory III and measurement category IV, the push-on caps
provided with the set and marked with CAT III and CAT IV must
be pushed onto the contact tips. The purpose of this measure
is user protection.
Remember that work on electrical components of all kinds is
dangerous. Even low-voltages of 30 V AC and 60 V DC may be
dangerous to human life.
Before starting the multimeter, always check it as well as all
measuring leads and wires for signs of damage.
Should it appear that safe operation of the multimeter is no longer possible, it
should be shut down immediately and secured to prevent that it is switched on
accidentally.
It may be assumed that safe operation is no longer possible:
-
if the instrument or the measuring leads show visible signs of damage, or
-
if the multimeter no longer works, or
-
after long periods of storage under unfavourable conditions, or
-
after being subject to rough transportation, or
-
if the device or the measuring leads are exposed to moisture.
In order to avoid danger,
-
do not touch the bare probe tips of the measuring leads,
-
insert the measurement leads in the appropriately
designated measuring sockets on the multimeter
Cleaning:
Regularly wipe the housing by means of a dry cloth and
cleaning agent. Do not use any polishing agents or solvents!
3.

Scope of delivery

The following items make up the standard BENNING MM 6-1/ MM 6-2 package:
3.1 one BENNING MM 6-1/ MM 6-2,
3.2 one safety measuring lead, red (L = 1.4 m),
3.3 one safety measuring lead, black (L = 1.4 m),
3.4 one wire temperature sensor, type K (only BENNING MM 6-1)
3.5 one protective rubber holster with magnetic holder,
3.6 one compact protection carrying case,
3.7 one 9 V block battery is integrated into the device,
3.8 one fuse for initial assembly is integrated into the device
(BENNING MM 6-2),
3.9 one operating manual.
02/ 2020
BENNING MM 6-1/ 6-2
21

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mm 6-2044087Mm 5-1Mm 5-2044070044071

Table des Matières