Note: Leave the fold-out page (chapter 11.1) open when installing the system.
The following parts are need for fitting:
1. Titanium anode (chapter 11.2, scope of supply (1))
2. Connecting cables (chapter 11.2, scope of supply (3))
3. Plug-in potentiostat (chapter 11.2, scope of supply (2))
4. Accessories (cf. Annex, Accessories / Insulated hole-mounting)
1 Seal (4)
1 Insulation sleeve with collar (5)
1 Washer (6)
1 Tooth-lock washer (7)
2 Hex nuts M8 (8 and 10)
1 Tooth-lock washer with tab connector 6.3 x 0.8 mm (9)
7.2.3 Installation of the CORREX
mounting
1. Empty the hot-water storage tank, if necessary.
2. For retrofitting, remove the old protective (Mg) anode, if any.
3. If not yet existing, drill a hole with a diameter of 10.5 mm into the
flange-type cover of the hot-water storage tank.
4. Slide the seal (4) over the threaded bolt of the titanium anode (1) and
pass the anode from the inside of the tank through the fitting bore.
5. Use the insulation sleeve with collar (5) for centering the M8 stud in the
10.5 mm bore of the flange-type cover.
6. Fasten the titanium anode together with insulation sleeve (5), washer (6),
tooth-lock washer (7) and hex nut (8).
Note: The screw fitting must be pressure-tight. The tightening torque is
8 Nm. Use a torque wrench.
7. Fit the tooth-lock washer with tab connector 6.3 x 0,8 mm (9) and fasten
with hex nut (10).
8. Refit the flange-type cover on the tank.
9. Fasten the spade terminal (11) at the end of the cable labelled „ground
connection tank" under the earthing screw of the tank. If the tank has no
earthing screw, the ground contact must be established by other
reliable means. Without a perfectly conducting galvanic connection, the
CORREX
10. Push the other connector at the tank end of the cable (12) - in this case
the receptacle 6.3x0.8 mm - on the tab terminal of the tooth-lock washer
of the anode.
11. Plug the two-pole connector (13) on the potentiostat side of the
connecting cable into the socket (14) of the plug-in potentiostat. Point the
MP 2.3-900 system for insulated-hole
®
MP 2.3-900 system cannot perform its function.
®
Operating Instructions CORREX
®
MP 2.3-900
35