6. Cleaning / Maintenance
Inside the extractor there are no parts which require maintenance.
Opening the device, other than for the processes described below, is not permissible!
6.1
Emptying the Dust Drawer
After 95 % of the set time (see section 5.6.3) has elapsed, the unit will demand the dust drawer to be
cleaned:
♦ The dust drawer symbol blinks (33, Fig. 2).
23
Remove dust drawer:
⇒ Pull the front panel off towards the front (4, Fig. 1).
⇒ Remove the locking plate entirely (23).
⇒ Open the fixture bracket (24).
⇒ Push the locking plate in completely above the dust drawer and hold it tight when pulling out the dust
drawer.
⇒ Pull out the dust drawer (5) and empty.
⇒ Check the profile seal on the dust drawer; change it if it is damaged.
Replace the dust drawer:
⇒ Push the entire dust drawer into the extraction unit.
⇒ Pull out the locking plate.
⇒ Close the fixture bracket.
⇒ Clean the locking plate.
⇒ Push the locking back underneath the dust drawer.
⇒ First place the base of the front panel onto the unit, then push the upper part of the panel against the
snap fasteners to close.
For the dust drawer to be correctly registered the suction must be switched on and the dust draw-
er must have been removed for at least 15 seconds.
6.2
Changing the Fine Filter
Do not wash the fine filter or try to clean it in any other way!
If the filter is damaged, there is a risk that the device will become damaged!
If the filter is damaged, please change immediately.
The filter is cleaned automatically on a regular basis (see section 5.5).
If the cleaning process starts to occur in increasingly short intervals, or if the suction performance is inad-
equate even after cleaning, then the fine filter must be changed.
Renfert recommends changing the fine filter every 2 to 3 years.
To change the fine filter:
Dismantle the fine filter:
⇒ Unpack the new fine filter and use the packag-
ing as a waste bag to dispose of the old fine
filter.
⇒ Switch the extraction unit on.
⇒ Pull the front panel off (4, Fig. 1) towards the
front.
⇒ Remove the 12 screws (26) from the cover
plate (24) and remove this.
⇒ Unscrew the fixing screws (25) from the fine
filter.
⇒ Tilt the fine filter (6) gently downwards and pull
out forwards.
⇒ Pack the fine filter into the waste bag and dis-
pose of properly.
24
24
- 19 -
26
EN
5
Fig. 24
25
6
Fig. 25

Publicité

loading