diode test
1
Set the function switch to the Ω CAP
2
Insert the black test lead banana plug into the negative COM jack and the red test lead banana
plug into the positive V jack.
3
Press the MODE button to display "
4
Touch the test probes to the diode under test. Forward voltage will typically indicate 0.400
to 0.700V. Reverse voltage will indicate "ol". Shorted devices will indicate near 0V and an
open device will indicate "ol" in both polarities.
position.
" and "V".