Safety warning!
For the illustration, see page 122.
2. INSTALLATION
Instructions which must be followed by the drive and home automation professional installing the Movelite
motor.
Never drop, knock, drill or submerge the drive.
Install a separate control point for each drive.
2.1. INSTALLATION
2.1.1. Installation of the rail (Fig A)
1) Mark the position of the brackets.
2) Drill the ceiling or the wall at the right places.
3) Attach the brackets.
4) Attach the rail on the brackets.
2.2. WIRING
(Fig C)
Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.
Attach cables to prevent any contact with moving parts.
Leave the drive power supply cable accessible: it must be possible to replace it easily.
Switch off the power supply.
-
Connect the drive according to the information in the table below:
-
AC wiring
(Fig C1)
Wire
1
Neutral
2
Live
3
Earth
DCT wiring
(Fig C2)
1
CCW (Open) NO Dry contact
2
3
Compatible controls - Wiring of control
1) Setting tool
2) Centralis IB
3) 2 NO (Normally Open) Dry contact switch
4
Caution!
2.1.2. Installation of the motor (Fig B)
1) Unlock the motor
2) Insert the motor shaft into the drive pulley hole.
3) Lock the motor.
100V to 240V
Blue
Brown
Yellow / Green
4
5
Ground Common
6
Copyright © 2017 - 2018 SOMFY ACTIVITÉS SA, Société Anonyme. All rights reserved
Information
Stop - NO Dry contact
CW (Close) NO Dry contact
(Fig D)