2.3. COMMISSIONING
DCT Setting tool
2.3.1. Setting the end limits
1) Switch on the power supply.
2) After the first Open or Close command, the motorised product will run at reduced speed to one end, then the
other, to set the End Stops.
2.3.2. Checking the direction of rotation (Fig E)
Move the curtain away from the end limits.
1) Press the Open button on the control point:
a) If the motorised product opens (a), the direction of rotation is correct.
b) If the motorised product closes (b), the direction of rotation is incorrect: Move onto the next step.
2) Press the Open , Stop and Close buttons, simultaneously until the motorised product moves
3) Press the Stop button, until the motorised product moves, to reverse the rotation direction.
4) Press the Open button on the control point to check the direction of rotation.
2.3.3. Adjusting the Touch motion sensitivity (Fig F)
1) Press the Open, Stop and Close buttons of the control point simultaneously until the motorised product moves.
2) Press the Open and Close buttons simultaneously until the motorised product moves to switch from high sensitivity, to low
sensitivity, to no touch motion, and back to high sensitivity.
3) Press the Stop button until the motorised product moves to confirm the setting.
2.3.4. Dry contact ergonomics setting : Standard or 2 buttons sequencing (Fig G)
1) Press the Open,Stop and Close buttons of the control point simultaneously until the motorised product moves.
2) Press the Stop and Close buttons of the control point simultaneously until the motorised product moves to change the
ergonomics.
2.4. TIPS AND RECOMMENDATIONS FOR INSTALLATION
2.4.1. Questions about the Movelite
Observations
The wiring is incorrect.
The motorised product does
The control point is not
not operate.
compatible.
2.4.2. Re-setting the end limits
Readjusting the Open end limit (Fig H)
1) Press the Open button to move the motorised product to the end limit to be readjusted.
2) Press the Open, Stop and Close buttons of the control point simultaneously until the motorised product moves.
3) Press the Open or Close button to move the motorised product to the new desired position.
4) To confirm the new end limit, press the Stop button until the motorised product moves.
Readjusting the Close end limit (Fig I)
1) Press the Close button to move the motorised product to the end limit to be readjusted.
2) Press the Open, Stop and Close buttons of the control point simultaneously until the motorised product moves.
3) Press the Open or Close button to move the motorised product to the new desired position.
4) To confirm the new end limit, press the Stop button until the motorised product moves.
2.4.3. Erasing the memory of the motor (Fig J)
Press and hold the Open, Stop and Close buttons simultaneously until the motorised product moves 3 times.
All the settings are erased.
Copyright © 2017 - 2018 SOMFY ACTIVITÉS SA, Société Anonyme. All rights reserved.
?
TM
Possible causes
Check and reconnect the power supply
Check for compatibility and replace the
control point if necessary.
EN
Open
Stop
Close
Solutions
5