3
Equipment controls
C) Wand control buttons
The ON button is used to give power to the cleaning
accessory. When the pumping mode is set to manual,
press the ON button to activate the pump. Press and keep
the button pressed to get conitunous flow of liquid,
However, if the pumping mode is set to automatic, press
the ON button once to activate the pump. To stop the
pump, press the OFF button. When finished working with
the machine (in either mode) make sure to press the OFF
button.
Once the ON button is pressed, there will be continuous
power at the tip until the OFF button is pressed.
ON
D) Fume elimination system (patented)
The SURFOX 205 machine comes with the integrated
fume elimination system. This system provides for better
work-ing conditions. Although the fumes are non-toxic and
non hazardous, they can be uncomfortable when working
in confined areas.
To activate this feature simply connect a compressed air
line (150 PSI max., 80 PSI min.) to the fitting at the back of
the machine. The fume elimination system is automatically
ac-tivated when the ON button is pressed on the Hand
Wand. The fume elimination system is turned OFF when
the OFF button on the Hand Wand is pressed. If the fume
elimination system is not wanted, simply disconnect the
compressed air line.
The working principle is quite simple and highly effective;
the air comes out through the small openings behind the
tungsten tip. This preset regulated air pressure condenses
the vapors out of the air.
6
OFF
E) Fastening inserts on the large wand
This unit comes with a quick-release adaptor on for the
cleaning acessories. The brush holder or tungsten insert
may be rotated counter clockwise to release it. Similarly,
you can fasten the cleaning accessories by rotating them
clockwise. You can also add the 2 x set screws to fix the
tungsten or the brush holder permanently.
Compressed
on-line fitting
Small
openings
Small
openings