Using The Mini Wand (Optional) To Clean And Passivate; Selecting The Proper Mode; Selecting The Proper Current Type; Ac Or Dc On Stainless Steel - Walter Surface Technologies SURFOX 205 Manuel De L'utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7

Using the mini wand (optional) to clean and passivate

Using the mini wand (optional) to clean and passivate
stainless steel or cleaning aluminum
Use the mini wand to get into tight places where the hand
wand cannot go. Plug the mini wand into the accessory
outlet on the front panel.
A) Selecting the proper mode
INOX / STAINLESS
When this mode is selected, it automatically cuts
the power to the hand wand, stops the solution
pump and the fume elimination system (if connected)
from operating. Only power is provided to the mini
wand/marking wand outlet. Be sure work piece is
grounded.
B) Selecting the proper current type,

AC or DC on stainless steel

Select AC for Cleaning and DC for Polishing. Level 1 has
the lowest amperage setting. Level 3 has the highest
amperage setting.
C) Selecting the proper current type,
AC or DC on aluminum
On aluminum, select AC for cleaning. DC mode will not
polish aluminum.
WARNING!
bead to match the mirror finish of the material.
TIP
. When using the polishing mode (DC), use
plenty of SURFOX electrolyte solution.
Note: When using DC setting, the SURFOX electrolyte solution will
become slightly yellow or will darken.
10
AC
Cleaning
Marking
DC mode is used to polish the weld
D) Manual pumping mode
The mini wand uses a manual pumping mode only. One (1)
press equals one (1) pump. To pump more liquid, press
repeatedly. See mini wand instructions for more information.
E) Cleaning and passivating
DC
Screw in SURFOX electrolyte solution 100 ml tube onto the
Polishing
mini wand. Make sure the cleaning pad or brush is saturated
Etching
with solution before starting to
work. If the accessory is too
dry, it will wear prematurely.
Start working when solution
drips from the cleaning pad.
Do not press hard, let the
electrochemical process do
the work. The accessory is a
bridge between the machine
and the weld. Do not use the
accessory like an abrasive pad.
F) Neutralizing
1. Remove any excess of SURFOX electrolyte cleaning
solution using a soft clean cloth or by rinsing with water.
2. Spray SURFOX-N on the surface.
3. Wipe dry with another soft clean cloth to avoid cross
contamination or by rinsing with water.
Refer to neutralization procedure in neutralization section
for instructions on how to properly neutralize.

Publicité

Table des Matières
loading

Table des Matières