Figure 5. Piping Diagram of The Tank For Boilers With Internal Pump And Three-Way Valve
TO SYSTEM
Z3
COLD
WATER
SUPPLY
*
Recirculation Line
See Figure 5 – Piping diagram indirect tank with boilers having an internal pump, three-way valve, and dedicated boiler water outlet for indirect tank. With
boiler working in the central heating mode, the three-way valve sends hot boiler water to CH supply. In DHW mode, the three-way valve diverts all boiler
water to the indirect tank supply.
Piping diagrams shown in Figures 4 and 5, zone pump configuration for the central heating is shown. They can also have a CH system pump and zone
valve configuration, with one CH system pump on the supply header. The Zone valve opens or shuts off the boiler water flow for each of the central heating
zones.
2. Install Pipes and Component
Follow piping installation instructions as shown in this manual with the piping guidance given in the appropriate hot water boiler Installation, Operation
Manual.
Quality installation and leak free connections, threaded or soldered, are the responsibility of the professional installer who carries out the work.
For all threaded connections, manufacturer recommends applying Teflon tape and pipe dope.
Teflon tape must be applied following the direction of the thread. The edge of the Teflon tape shall not go beyond the end of the thread. The pipe dope shall