4 Remove the end cap from the toothbrush
handle. If the end cap does not release
easily from the housing, repeat step 3 until
the end cap is released.
5 Holding the handle upside down, press the
shaft down on a hard surface. If the internal
components do not easily release from the
housing, repeat step 3 until the internal
components are released.
6 Wedge the screwdriver between the battery
and the white frame at the bottom of the
internal components. Then pry the
screwdriver away from the battery to break
the bottom of the white frame.
7 Insert the screwdriver between the bottom
of the battery and the white frame to break
the metal tab connecting the battery to the
green printed circuit board. This will release
the bottom end of the battery from the
frame.
8 Grab the battery and pull it away from the
internal components to break the second
metal battery tab.