Installing Grill on custom built cabinet
The installation must conform with local codes or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, Storage and Handling of Liquefied Petroleum
Gases, ANSI/NFPA 58; or Natural Gas and Propane Installation Code, CSA B149.1; Propane
Storage and Handling. If you are connecting an appliance to a fixed fuel piping system
specifying the use of a rigid pipe, semi-rigid tubing, and/ or a connector that complies
with the standard for Connectors for Outdoor Gas Appliances and Manufactured Homes,
ANSI Z21.75
CSA 6.27.
WARNING
Cabinet frame, cabinet side
panels and counter top must be
made from non-combustible
material.
1. DO NOT store or use products with flammable liquids or vapors in the vicinity of the NewAge
Grill Cabinet,NewAge Outdoor Kitchen cabinets or any appliances.
2. DO NOT store a spare Propane gas cylinder in or near the NewAge Grill Cabinet, NewAge
Outdoor Kitchen Cabinets, or any other appliances.
CLEARANCES:
TO NON-COMBUSTIBLE CONSTRUCTION
A minimum of 4" (10 cm) clearance from the back of the grill to non-combustible construction is
required to allow the hood to be opened fully.
TO COMBUSTIBLE CONSTRUCTION
This appliance should NOT be installed over, under or next to unprotected combustible
construction. A minimum clearance to vertical and rear combustible material is 18" (45 cm) and 14"
(36cm) on the sides.
The minimum vertical clearance to combustible materials means that ALL combustible materials
must be outside this 18" (45cm) zone. As an example, if you have an island with a stucco or
tiled surface and wood-frame construction beneath, the wood is considered combustible, even
though the grill is touching the stucco or tile surface, which is non-combustible. In extreme
circumstances, the wood could potentially get hot enough to burn.
VENTILATION OPENINGS
A minimum of three 10 in² (65 cm²) of ventilation openings must be provided at the bottom of both
left and right sides of your enclosure (island), as well as the back side. A minimum of three 20 in²
( 130 cm²) of ventilation openings must be provided at the top of both left, right and back sides of
your enclosure (island) where the top of the opening aligns with the bottom of the grill cut-out.
These openings are required to safely dissipate gas vapors if there is a leak in your enclosure.
16
A propane tank can not be stored
below the gas grill. Only 1 max 20 lbs
(12.125in x 17.75in) tank in service
should be used with the Grill.
WARNING
WARNING