Leak Testing Instructions
Fixing a Gas Leak
•
Shut off the gas supply.
•
Turn all grill controls to the "ON" position to purge the grill of any gas build-up, then turn the
controls back "OFF".
•
Wash off the soapy solution with cold water and dry.
•
Tighten the loose joint, or replace the faulty part with manufacturer-recommended replacement
parts.
•
DO NOT attempt to repair the Propane gas cylinder valve if it is damaged. The only way to safely
resolve a damaged cylinder is to REPLACE IT.
•
Repeat the leak test to ensure that no leaks are present.
•
If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have
the grill inspected by a licensed gas fitter or dealer. Do not use the grill until the leak has been
corrected.
36