Technical Specifications - Rocal D-10 Graffiti Manuel Des Caracteristiques, Installation Et Fonctionnement

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1. SPECIFICATIONS

1.1 Technical specifications

Parameter
Minimum - Maximum draught
Fuel consumption
Smoke mass flow rate
Performance
Nominal output
Power range
Average CO concentration at 13% of O
Particle concentration
Average NO
concentration at 13% of O
x
Average OGC concentration at 13% of O
Medium draft (trial)
Net weight
Maximum authorized load (fuel)
Reload height
Logs length
Minimum flue height
Ø Flue duct
Ø Air inlet
Front safety distance
Side safety distance
Back safety distance
Average temperature of smoke
Type of combustion
Flue liner
Fuel
Humidity fuel logs
Certification year
Certificate No.:
1.2 Breakdown of delivery components
(
Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
1. Fireplace's body.
2. Cover pipe
3. Ceiling crest
4. Upper baffle to limit the draught.
5. Bag with 4x screws and 4x anchor to install the ceiling plate.
6. Fixative of the aluminium ring with 4x screws to install it.
7. Exterior air inlet cover with 4x screws to install it.
8. Aluminium ring to connect external air intake.
9. Metal clamp.
10. Bag with 7x metallic anchors.
11. Documentation bag: output declaration, energy label, guarantee, technical sheet, and installation and operating
characteristics manual.
12. Heat-resistant glove.
13. Cleaning cloth.
14. Heat-resistant spray paint for touch-ups.
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I
2. REQUIREMENTS PRIOR TO INSTALLATION
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH UPON
INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground. In case it is installed with the optional foot support, make sure the ground where the appliance will be placed is able to
support the weight of the device. If not, you will need a load spreading plate for the equitable distribution of the equipment's weight.
In case of doubt, please consult a specialist.
2.2 Wall. If installed hanging, make sure the wall where the device will be placed has enough load capacity to support the weight of
the device —see the table below with the technical characteristics of the anchor. If this is not the case, a loading plate should be used
to share the load in order to have an equitable distribution of the device's weight. In case of doubt, ask a specialist.
2
2
2
Value
11-13 Pa
3,24 kg/h
10,4 g/s
78,3 %
11,3 kW
8 – 13.5 kW
0,084%
16 mg/Nm
122 mg/Nm
51 mg/Nm
12,2 Pa
144 kg
200 mm
330 mm
4000 mm
150 mm
120 mm
1000 mm
500 mm
200 mm
279,2 º C
INTERMITTENT
NOT SHARED
NATURAL WOOD
12-20% - two years under cover
1880-CPR-072-20
3
3
3
4 kg
2020
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

X1267

Table des Matières