1. SPECIFICATIONS

1.1 Technical specifications

Parameter
Minimum - Maximum draught
Fuel consumption
Smoke mass flow rate
Performance
Nominal output
Power range
Average CO concentration at 13% of O2
Particle concentration
Medium draft (trial)
Net weight
Maximum authorized load (fuel)
Reload height
Logs length
Minimum flue height
Ø Flue duct
Ø Air inlet
Front safety distance
Side safety distance
Back safety distance
Average temperature of smoke
Type of combustion
Flue liner
Fuel
Humidity fuel logs
Certification year
Certificate No.:
1.2 Breakdown of delivery components
(
Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
1. Fireplace's body
2. Flue liner connector
3. Ceiling plate
4. Upper baffle to limit the draught
5. Aluminium ring to connect
6. Heat-resistant glove
7. Cleaning cloth
8. Documentation bag: output declaration, energy label, guarantee, technical sheet, and installation and operating
characteristics manual.
9. Metal clamp
10. Bag with metallic anchors
11. Heat-resistant spray paint for touch-ups
12. Bag with screws and anchors
13. Fixative of the aluminium ring
14. Exterior air inlet cover
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I
2. REQUIREMENTS PRIOR TO INSTALLATION
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH UPON
INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground. In case it is installed with the optional foot support, make sure the ground where the appliance will be placed is able to
support the weight of the device. If not, you will need a load spreading plate for the equitable distribution of the equipment's weight.
In case of doubt, please consult a specialist.
2.2 Wall. If installed hanging, make sure the wall where the device will be placed has enough load capacity to support the weight of
the device —see the table below with the technical characteristics of the anchor. If this is not the case, a loading plate should be used
to share the load in order to have an equitable distribution of the device's weight. In case of doubt, ask a specialist.
Value
11-13 Pa
2.6 kg/h
6.4 g/s
9.4 kW
6 – 11 kW
0.08%
27,07 mg/Nm
12 Pa
150 kg
200 mm
300 mm
4000 mm
150 mm
120 mm
1000 mm
800 mm
600 mm
214º C
11-13 Pa
NOT SHARED
NATURAL WOOD
12-20% - two years under cover
17/14327-1020/1021
84 %
3
4 kg
2017
10

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

X1292