INSTALLATION

Safety

INSTALLATION
9.
Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
9.1

General safety instructions

We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
9.2

Instructions, standards and regulations

Note
Observe all applicable national and regional regulations
and instructions.
- Install the appliance in such a way that control equipment
cannot be touched by a person in the bath or shower.
- All electrical connection and installation work must be car-
ried out in accordance with VDE regulations (DIN VDE 0100)
[or local regulations], the rules of your local power supply
utility, and relevant national and local regulations.
- Only mount the appliance on a vertical wall that is tempera-
ture-resistant to at least 85 °C.
- Maintain minimum clearances to adjacent surfaces.
- Ensure the on-site cable has an adequate cross-section.
- If connecting the appliance via a socket, ensure that this is
easily accessible once the appliance has been installed.
- Never install the appliance directly below a wall socket.
- When installing the heating appliance in rooms with a bath
or shower, observe the safety zone according to VDE 0100,
section 701 [or local regulations], in accordance with the de-
tails on the appliance type plate.
- Observe the type plate. The specified voltage must match the
mains voltage.
- Observe the Building and Garage Regulations [or local
regulations].
22
| CK 20 Trend LCD
All manuals and user guides at all-guides.com

10. Appliance description

10.1 Standard delivery

The following are delivered with the appliance:
- 1 wall mounting bracket

10.2 Accessories

- Towel holder

11. Preparation

11.1 Installation location

Minimum clearances
≥500
≥100
≥10
CAUTION Injury
!
f Maintain the minimum clearances.
f If you are using the appliance together with a towel
rail, fit the appliance so that the towel rail is at least
600 mm above floor level.
Note
For efficient heating (without towel rail), we recommend
an installed height of between 300 and 500 mm.
Note
The dust filter is 275 mm wide.
- To enable removal of the dust filter as described (see
chapter "Cleaning, care and maintenance"), maintain
a sufficiently large clearance at the side.
- If you have installed the appliance in a recess, de-
tach the appliance from the wall mounting bracket
before removing the dust filter.
≥100
www.stiebel-eltron.com