Remove the spout holder (A2) by loosening the two Allen
screws (H2).
Then proceed to remove seal (E2) using a screw driver.
After removing the seal undertake to clean the slot and
then re-assemble the new seal taking care to insert it with
the chamfered part turned upwards towards the unit itself.
8.3

Purifier Regeneration

Regenerate the purifier at
the intervals listed below:
HARDNESS °F
8 LITRE PURIFIER
From 00 to 20
regeneration after 1100 l
From 21 to 30
regeneration after 850 l
regeneration after 650 l
From 31 to 40
From 41 to 50
regeneration after 450 l
These
instructions are valid only
providing the purifier is as
that indicated in the figures.
Should it fail to correspond
proceed as indicated in the
instructions attached to the
purifier itself.
12 LITRE PURIFIER
regeneration after 1600 l
regeneration after 1250 l
regeneration after 950 l
Place the empty 2 litre container under pipe E3. Shift
regeneration after 650 l
levers C3 and D3 from left to right and remove the cover
by loosening knob G3, pour in 1.5 kg of sodium chloride
(coarse cooking salt) into the 8-litre purifier and 2 kg into
regeneration
the 12-litre type.
A3
Water Inlet
B3
Water Output
C3
Inlet Tap Lever
D3
Output Tap Lever
E3
Depressurizer Pipe
F3
Regeneration Tube
G3
Cover Knob