Connect the power cable (I) to the electric line using a plug, or in
the case of fixed installation, using a multi-polar switch (D) for
mains separation, with a contact distance of at least 3 mm.
Connect motor pump (C) cable to motor pump (E).
For voltage change refer to the diagram shown on the general
mains switch box.
The yellow-green coloured
cable MUST be connected
to the room's earthing
system.
Depending on the current
regulations of the Country
where the machine operates,
the cable connecting the
electric line has to be pre-set
or equipped with an all-pole
switch (with a minimum
contact opening of 3 mm),
(or with a plug in accordance
with the same regulations).
It is recommended to install a
residual current device (RCD)
with a rated residual current
not exceeding 30 mA.
If the supply cord is damaged,
it must be replaced by the
manufacturer, its service agent
or similarly qualified persons in
order to avoid a hazard.
Connect the motor pump power cord (C) as shown in the figure.