Operating mode
Direct current
Overload protection see below
Alternating current 400µA
Frequency of the alternating current: 50Hz to 400Hz
Overload protection see below
Resistance
Continuity tester: acoustic signal for resistance values
Capacity
C
Diode test
Test voltage 1mA max.; emitter diode voltage max. 1.5V
Frequency
Sensitivity higher or equal to ca. 300mVeff from 1Hz to 1MHz
Sensitivity higher or equal to ca. 600mVeff from 1MHz to 10MHz
Measurement range Accuracy
400µA
4000µA
40mA
400mA
4A
20A
4000µA
40mA
400mA
4A
20A
400 ohm
4kohm
40kohm
400kohm
4 MOhm
40 MOhm
< ca. 70 ohm
40nF
400nF
4µF
40µF
100µF
Ge to GaAs
5Hz
50Hz
500Hz
5kHz
50kHz
500kHz
5MHz
10MHz
±(1.0%+5dgts)
±(1.0%+5dgts)
±(1.2%+5dgts)
±(1.2%+5dgts)
±(1.5%+5dgts)
±(1.5%+5dgts)
±(2.0%+5dgts)
±(2.0%+5dgts)
±(2.0%+5dgts)
±(2.0%+5dgts)
±(2.5%+5dgts)
±(2.5%+5dgts)
±(1.2%+2dgts)
±(1.0%+2dgts)
±(1.0%+2dgts)
±(1.0%+2dgts)
±(1.2%+2dgts)
±(1.5%+2dgts)
±(3.0%+10dgts)
±(3.0%+5dgts)
±(3.0%+5dgts)
±(3.0%+5dgts)
±(4.0%+5dgts)
±(0.1%+3dgts)
±(0.1%+3dgts)
±(0.1%+3dgts)
±(0.1%+3dgts)
±(0.1%+3dgts)
±(0.1%+3dgts)
±(0.1%+3dgts)
±(0.1%+3dgts)
Resolution
0.1µA
1µA
0.01mA
0.1mA
0.001A
0.01A
0.1µA
1µA
0.01mA
0.1mA
0.001A
0.01A
0.1 ohm
0.001kohm
0.01kohm
0.1kohm
0.001MOhm
0.01MOhm
0.01nF
0.1nF
0.001µF
0.01µF
0.1µF
1mV
0.001Hz
0.01Hz
0.1Hz
0.001kHz
0.01kHz
0.1kH
0.001MHz
0.01MHz
35