Télécharger Imprimer la page

SSS Siedle DCA 650-02 Information Produit page 5

Masquer les pouces Voir aussi pour DCA 650-02:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
DCA 650-... must be supplied sepa-
rately with a transformer.
• It is not possible to update the
DCA 650.0 from V1.x to V2.0 for
technical reasons.
Remark relating to the declara-
tion of conformity
We, S. Siedle & Söhne hereby
declare that this device is in agree-
ment with the underlying require-
ments and other relevant stipulations
of the 1999/5/U directive. The decla-
ration of conformity can be accessed
in the download sector of the
internet address www.siedle.com.
This device is used for communica-
tion between public telephone
networks. It can be operated in
those European networks which
correspond to the TBR-21 standard.
Please contact your dealer or tel-
ephone provider if you are not sure
whether your telephone connection
is TBR-21-compatible.
Conductor routing
In order to comply with the general
safety regulations for telecom-
munication systems in accordance
with VDE 0100 and VDE 0800, and
to prevent electrical interference,
ensure separate routing of heavy
and light current conductors. A dis-
tance of 10 cm must be adhered to.
The conductor from the door
loudspeaker must be laid directly
to the main terminal box without
branching.
Range
The maximum range between the
TR 603-... and the DCA 650-... is
20 m with a 0.8 mm core diameter.
Mounting
1 Mount the DoorCom Analog on
the top-hat rail (distribution)
2 Surface mounting with accessory
ZAP 6-0
3 Volume control -
P1 in the direction to the door
P2 in the direction to the telephone
Installation and commissioning
Installation, commissioning and
programming are described in the
system manual (enclosed with line
rectifiers BNG/BVNG 650-... ).
Terminal assignment
Ta
In-Home-Bus
Tb
La
analog telephone
Lb
connection
b
12 V AC supply
c
Specifications
Operating voltage: 12 V AC
Operating current: max. 100 mA
Ambient temperature: 0°C to +40°C
Horizontal pitch (HP): 6
Dimensions (mm) W x H x D:
107 x 89 x 60
5

Publicité

loading