Télécharger Imprimer la page

SSS Siedle DCA 612-0 Information Produit page 4

Masquer les pouces Voir aussi pour DCA 612-0:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
Installation und Inbetriebnahme
Installation und Inbetriebnahme sind
im Systemhandbuch 1+n-Technik
beschrieben (liegt dem Netzgerät
NG 602-... bei).
Klemmenbelegung
7.1
Rufeingang 1
7.2
Rufeingang 2
7.3
Rufeingang 3
1
Systemader im 1+n-System
La
analoger Telefonanschluss
Lb
b
Versorgung 12 V AC
c
Technische Daten
Betriebsspannung: 12 V AC
Betriebsstrom: max. 100 mA
Umgebungstemperatur:
0°C bis +40°C
Teilungseinheit (TE): 6
Abmessungen (mm) B x H x T:
107 x 89 x 60
4
English
Application
DoorCom-Analog in switch panel
housing as an interface for the 1+n
technology links the door station to
the public network.
• 3 door call inputs
• Max. 6 control functions can be
executed via SFC 602-... using
DTMF dialling corresponding to
HTC 811 -...
• Selective dialling of max. 3 door
loudspeakers when using interface
DCSF 600-... and additional wiring
• Two-line alphanumeric display with
16 characters per line
• 6 buttons: convenient configura-
tion
• Same functions as a system tel-
ephone
• The following call possibilities can
be assigned (each max. 22 digits
long)
• Direct calls
– Selective user call
– Group calls (dep. on the telephone
system)
– Collective calls (dep. on the tel-
ephone system)
– Calls to PBX extensions, to public
network or mobile phones
• Chain calls
– In case of no answer or engaged
• System functions door release
and light using the DTMF dialling
method
• Doormatic function for 1 call
input, with/without previous door
call signal
• Call rerouting to e.g. concierge
• Day/night service to alternative call
destinations (depending on custom-
er's existing telephone system)
• Switching from door intercom to
telephone mode
• Several DCA units possible in one
intercom system/one telephone
system
• Adjustable call and connection
time
• Signalling of door calls prior to call
acceptance
• Call differentiation possible for
doors or call inputs (max. 2)
• PIN protection can be activated
e.g. for programming, door release,
switching functions and function
activation
• Time-controlled activation/deac-
tivation of e.g. Doormatic, call
rerouting, day and night service etc.
possible via DCSF 600-... accessory
and customer's time switches
• Jack for HT 811-... servicing
handset
For connection of existing on-site
PBX systems with an analogue tel-
ephone connection in accordance
with TBR-21
The DCA 612-... can be operated in
the countries DE, GB, FR, IT, NL, DK,
CH and AT and must always be con-
nected to a standardized a/b output
(as per TBR-21).
• The DCA 612-... must be supplied
separately with 12 V AC, e.g.
TR 603-...
Note
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualified
electrician.
• Participants must be able to dial
DTMF.
• Subscribers are dialled using the
DTMF digits 0 - 9, *, # and F (flash
pulse with 100 ms).
• Up to 3 call buttons are managed
by the DCA 612-.... For each of the
three connected call buttons, an
optional call number can be issued
(max. 22 digits).
• Door release and light actuation
take place by means of multiple fre-
quency dialling.
• A switching / remote control inter-
face DCSF 600-... can be integrated
into the DCA 612-..., making avail-
able 3 floating outputs and 3 inputs
via optocoupler.
• If there are several DCA 612-...
units existing in the system, each
must have a separate power supply.

Publicité

loading