Les langues disponibles

5.
MAINTENANCE
M
5.3
ASTER
Use the master reset only if you perform the annual maintenance before the annual
maintenance indicator is on. By inserting a small rod (e.g.: paper clip end) during 5 seconds
and more into the reset filter hole of the wall control, a master reset will be done and both
biannual and annual maintenance filter are reset.
If the wall control is in Off position, Fresh air light indicator will flash for 1 second.
If the wall control is in Normal or Boost position, the unit motor and the Fresh air light
indicator will turn off for 3 seconds.
If the wall control is in Recirculation position, the unit motor will turn off during 3 seconds.
6.

TROUBLESHOOTING

PROBLEMS
1. Unit does not start at Normal
or Boost position.
2. Unit does not run at Normal
speed, but runs at Boost.
3. Unit is not operating as per
the selected mode.
4. Wall control indicators do not
work properly or not at all.
5. Air too dry.
6. Persistant condensation.
If the problem is still not solved, call your installer or the nearest approved Service
Center.
Also, you can reach the Customer Service Department at the following telephone numbers:
(CONT'D)
R
ESET
• Check breaker or fuse in main distribution panel.
• Check there is 120V at the electrical outlet.
• Check control wiring and wall control connections.
• Check wall control wiring.
• Check wall control wiring.
• Avoid operating the unit on BOOST mode.
• Use the Recirculation mode.
• Turn on the central heating system.
• Store the firewood outside the house.
• Do not completely close curtains, blinds, etc.
Exclusively for model AE60:
1-800-637-1453.
Exclusively for model EA1500:
1-800-567-3855.
Exclusively for model HV 1.5:
1-866-737-7770.
SOLUTIONS