Commandes HART supportées :
SITRANS Probe LR est conforme à la révision 5 de HART. Le système supporte les
commandes suivantes :
Commandes universelles
0, 1, 2, 6, 7, 8, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22
Commandes d'utilisation commune
33, 34, 35, 36, 37, 38, 40,41, 42, 44, 45, 46, 48, 50, 51, 53, 54, 59, 110
Commandes spécifiques à l'appareil
Command 138
Command 139
Command 140
Command 160
Command 161
Command 162
Command 163
Command 164
Command 165
Command 166
Command 167
Command 168
Command 169
Command 170
Command 171
Command 172
Command 173
Command 174
Command 175
Command 176
Command 178
Command 179
Command 180
Command 181
Command 182
Command 183
Command 184
Command 185
Command 186
Page 78
SITRANS Probe LR – MANUEL D'UTILISATION
Read the user specific characteristics
Write the user specific characteristics
Perform Device Specific Configuration
Read Quick Setup
Write Quick Setup
Read Volume
Write Volume
Read Volume Breakpoint
Write Volume Breakpoint
Read Failsafe
Write Failsafe
Read Echo Data
Write Echo Data
Read Echo Lock
Write Echo Lock
Read TVT
Write TVT
Read TVT Shaper
Write TVT Shaper
Read Confidence
Read Analog Special
Write Analog Special
Read Local Display Commands
Write Local Display Commands
Read Range Calibration
Write Range Calibration
Read Serial Port Settings
Write Serial Port Setting
Read Wear
7ML19985HR11