- Stop the refrigerating system (by switching off
all the LED acting on the – button or by pressing
the +button and keep it pressed to switch off
the defrost mode) and let the machine run with
the only auger activated (all LED switched off)
for ten minutes.
- Provide yourself with a sanitizer suitable for
plastic, rubber and stainless steel objects
(AMUCHINA®).
IMPORTANT
Carefully follow the mix producer
prescriptions in terms of time and modes
of conservation.
- Remove the cover (fig.12).
- Pour lukewarm water into the bowl (fig.13)
and, after re-positioning the cover, make the
scraper auger rotating for some minutes (all
LED switched off).
Each bowl is equipped with a very efficient
safety mechanism, activated when the cover is
lifted, designed to protect the operator. If the
cover is not correctly positioned, NINA1
will not work.
- Empty the bowl and repeat the same
operations until the coming out water is clear
(fig.14).
Data di emissione: December, 2013
NOTE
Revisione: 1
Fig. 12
Fig. 13
Fig. 14
Pag. : 52/68