CAT3 PRO
6.3 Connecting the helix cable
1
1
Cable assembly
2
Flange plug
Fig. 11
1 Plug the helix cable (6) into the connector housing (4) using the angled male connector (5).
2 Insert the flange plug (2) in the welding torch (3) or cable assembly (1).
3 Lock both connectors to prevent their accidental disconnection.
For the switching function please see the functional diagram.
Fig. 7 Functional diagram (PINs mating side view) on page EN-12
7 Operation
NOTICE
• Only qualified personnel are permitted to perform work on the device or system.
• Consult the documentation for the welding components.
As the CAT3 PRO is integrated into the torch's welding process, the operating steps are
performed after the respective torch has been put into operation.
BAL.0843.0 • 2021-02-26
2
6
5
3
Welding torch
4
CAT 3 connector housing
Connecting the helix cable
3
4
7 Operation
5
Angled male connector
6
Helix cable
EN - 17