EN
5D
15. Connect the Hot Water Supply Hose
(red) to the Hot water supply in the
home (red) as indicated in figure 5D.
16. Remove Spray Aerator (16) using
the Spray Aerator Key (17) and remove
Spout Aerator (18) using the Spout
Aerator Key (19) (fig. 5E).
CLEANING AND MAINTENANCE
Replacing the cartridge
1. Shut off the water supply to the faucet.
2. Turn on the faucet briefly to relieve
any pressure inside the faucet.
3. Move the faucet handle to the
"OFF" position.
4. Remove the set screw from the handle
assembly (A) using a 2.5 mm hex key.
5. Pull handle assembly (A) from
faucet body.
6. Unscrew the cartridge cap (B) from
faucet body.
7. Unscrew the cartridge lock nut (C).
8. Lift ceramic disc cartridge (D) from
the body and replace it with a new one.
Ensure the two lugs on bottom of the
cartridge sit properly in the allocated
holes at the base of the body.
9. Re-assemble faucet in reverse order.
10. Test for leakage.
13
14
5E
9
16
17
17. Turn on water, flush the faucet and
both Aerators (16 and 18) to remove any
15
debris and check for leaks (fig. 5F).
18. Reinstall the Aerators (16 and 18)
in reverse and ensure everything is
functioning properly.
5F
16
General maintenance
Clean aerator periodically for any buildup.
Do not use harsh detergents, solvents,
chemical agents or metallic sponges as
these can damage the surface finish.
Clean only with a soft sponge and
soapy water.
Do not store chemicals or cleaning
agents in the immediate vicinity of the
faucet and connection hoses. Chemical
vapors could cause damage.