10. Connect the 3/8" Poly Tubing (9) to
the Drinking Water Fitting (10) and cut the
Poly Tubing (9) to proper length to remove
any unnecessary loops or low spots as
shown in figure 5A. Save excess Poly
Tubing (9) for water filtration connection.
IMPORTANT: When using push fittings,
ensure the ends of the tubing are cut
square and free of burrs or damage within
1" of the end of the tube. DO NOT use
any forms of sealing compounds or tools
to remove the tubing or modify the fitting
in any way, as this can damage the fitting
and result in leaks. Proper installation
and removal of tubing with push fittings is
outlined in figure 5B. Damage in this area
can cause leaks.
5A
11
10
9
How to insert / Remove Tubing
In Push Fit Connections
1. Insert the tubing squarely. See fig. 5B-1.
2. Make sure to insert tubing completely.
See fig. 5B-2.
3. To remove, push in collet and pull out
tubing. See fig. 5B-3.
5B
5B-1
5B-2
5b-3
– 9 –
11. Connect the Check Valve Holders (12)
to the Hot and Cold Supply Hoses
(red/blue) from the faucet as illustrated in
figure 5C.
5C
12
12. Connect the 3/8" Poly Tubing (9) to
the exit of the Water Filter (15), which
is NOT included with the faucet, as
illustrated in figure 5D.
IMPORTANT: Franke strongly
recommends using only genuine Franke
water filtration products with this faucet.
The installation or function of the faucet
can't be guaranteed if using other
filtration products.
13. Connect the Shut-off Valve (13)
to the Cold Water Supply in the home
(blue) and connect the other side to the
Cold Water Supply Hose (blue) from the
faucet as illustrated in figure 5D.
IMPORTANT: DO NOT over-tighten
threaded connections for the shut-off
valve (13). DO NOT exceed 25 In-lbs of
torque.
14. Take excess 3/8" Poly Tubing (14)
from Step 10 and connect one end to
the push fitting connection of the Shut-
off Valve (13). Take the other end and
connect it to the inlet of the Water
Filter (15). See figure 5D for overview.