Attention
To avoid risk of electrical shock or contact
with moving parts during dismantling and
reassembly, make sure all switches are in
the off position and that the power lead is
disconnected from the mains.
- Turn off the main switch A (neutral position)
and disconnect the power lead from the mains.
- Unscrew the security knobs and remove the
front flange (fig. 14 and 15).
- Wash and disinfect hands thoroughly before
performing cleaning operations otherwise use
clean and sanitized gloves.
- Simultaneously apply pressure to the two
securing tabs (Q), and lift the dispensing tap (I)
to pull it out of its fixed position (see figure 16).
- Disassemble the dispensing tap by keeping the
indicated part (R) pressed down and slipping off
the dispensing lever (L) (see figure 17).
- Thoroughly wash each single part with hot
water and mild dishwashing detergent/soap,
rinse well, and dip each piece in the sanitising
product according to the doses and immersion
times suggested by its manufacturer.
To prevent bacteria growth, remove all
o-rings when cleaning.
Failure to do so could create a health
Date of issue: September 2018
Caution
hazard.
Revision 4
Fig. 14
Fig. 15
Fig. 16
Fig. 17