The machine then presses the pipes automatically together.
4.3.7

Joining and Cooling Stage

In the joining stage the machine increases pressure in ac-
cordance with the pressure ramp computed for the joint
(see Display 28). During this stage LED 5 flashes; all previous
LEDs are lit.
When the full joining pressure is reached, the machine
moves on to the cooling stage (see Display 29). The cooling-
down is represented as a countdown of remaining duration.
During cooling, the joining pressure applied is monitored.
In the process, LED 6 flashes, all the previous LEDs are lit.
Some standard, e.g., DVS, require the joining pres-
sure to be the same throughout cooling (t
have it that the initial joining pressure (t
Info
reduced after some time into cooling (t
a standard was selected, the machine takes care of
the pressure reduction required by the standard. In
that stage LED 7 flashes, all the other LEDs are lit.
4.3.8

End of Welding

A beep signals the end of the cooling time. Furthermore,
the green LED is lit to indicate a successful welding process.
Confirm the end of welding by pressing the START/SET key.
Pressure to the hydraulic lines will then be shut off.
Note in general that pursuant to DVS 2207-1 or oth-
er international standards, the cooling time has to
be observed and waited out for its entire length.
Info
A reduction of the cooling time of up to 50%, i.e.,
joining pressure release and removal of the welded
part from the welding system, is allowed in the fol-
lowing conditions:
• the welding is done in workshop conditions and
• the removal from the welding equipment and
the temporary storage are causing only slight
loads to the joint and
• it concerns components with a wall thickness of
≥ 15 mm.
Under the welder's responsibility, the cooling
time can be reduced and the welding operation
ended early, by pressing the START/SET key if at
least half of the cooling time is over. A welding op-
eration with reduced-duration cooling is identified
in the report, if the HCD feature is enabled in the
Recording menu (refer to Sect. 4.1.6), by the indica-
tor -HC- .
26
EN
HÜRNER CNC ECO 200 2.0 User's Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
JOINING PHASE
230°C
229°C
COOLING PHASE
Cooling time :1234s
230°C
229°C
). Others
5
) must be
5
). If such
6
COOLING PHASE
Cooling time over
229°C
Nieder-Ohmener Str. 26
35325 Mücke, Germany
NOM.
16.5bar
ACT.
14.5bar
Display 28
NOM.
16.5bar
ACT.
16.5bar
Display 29
ACT.
0.0bar
Display 30
Version October 2022

Publicité

Table des Matières
loading

Table des Matières