micro CA-100 Inspection Camera

Operating Instructions

WARNING
Always wear eye protection to protect
your eyes against dirt and other foreign
objects.
Follow operating instructions to reduce
the risk of injury from electrical shock,
entanglement and other causes.
1. Make sure that the inspection camera
and work area have been properly set up
and that the work area is free of by-
standers and other distractions.
Rotate
Image
LED
Brightness Decrease
Figure 8 – Controls
2. Power On: Press and Hold the power
button for 3 seconds.
The power status light will come ON. If
the power status light is GREEN, the
micro CA-100 Inspection Camera bat-
teries are good. If the power status light is
RED, the batteries need to be changed. If
the LED does not turn ON, the batteries
need to be changed or the unit needs
service. The splash screen will appear.
3. Pre-Form The Cable: If needed for the
area to be inspected, pre-form the cable.
Do not try to form bends with a radius of
less than 2", this can damage the cable.
8
4. LED Brightness Adjustment: Turn the
5. Inspection: Insert the imager head and
6. Image Rotation: If needed, the image
7. Power Off: When the inspection is com-

Viewing

The micro CA-100 Inspection Camera can be
connected to a television or other monitor for
Battery
remote viewing or recording through the in-
Indicator
cluded RCA cable. Open the rubber cover on
the side of the grip and insert the RCA cable
into the TV-OUT jack.
Power
Insert the other end into the Video In jack on
LED Brightness
the television or monitor. The television or
Increase
monitor may need to be set to the proper
input to allow viewing.
Figure 9 – TV-OUT Jack/Reset Button
LEDs ON. The imager head is equipped
with four white LEDs to aid inspection.
Use the + and – buttons to turn ON and
adjust the brightness of the LEDs.
cable into the space to be inspected. Do
not use the imager head or cable for
anything other than an inspection de-
vice. Do not use the imager head and
cable to clear a path. Do not force the im-
ager head and cable through tight bends
or spaces. These uses can damage the
unit and the area to be inspected.
seen on the screen can be rotated in 90
degree increments counter clockwise by
pressing the rotate image button.
plete, carefully withdraw the imager and
cable from the inspection area. Press
and Hold the power button for 1 second
to turn the unit OFF. The unit will auto-
matically turn OFF 30 minutes after the
last button press or if the batteries drop
too low.