CONFORMITY WITH STANDARDS

Electrical safety (in accordance with IEC 1010-2-032)
- Dual insulation:
- Installation category: I I I
- Degree of pollution: 2
- Service voltage: 600V RMS
Mechanical protection
- Watertightness: protective index IP40 (in accordance with IEC 529)
- Max. drop: 1m (in accordance with IEC 1010)
- Shocks: 100 g (in accordance with IEC 68.2.27)
- Vibrations: 0.15mm peak (in accordance with IEC 68.2.6)
Fields and radiation
- Electrostatic discharge: 4kV - class 2 (in accordance with IEC 801-2)
- Radiated field: 10V/m - class 3 (in accordance with IEC 801-3)
- Rapid transients: 2kV - class 3 (in accordance with IEC 801-4)
- Electric shocks: 6kV - (in accordance with IEC 801-5)
Self extinguishing V2 (in accordance with UL94)