Change Parameters - Parker Hyperchill-Plus ICEP007 Manuel D'utilisation

Masquer les pouces Voir aussi pour Hyperchill-Plus ICEP007:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.4.3
Energy saving temperature control
PARAMETER
CODE
ESE
energy saving enable
Set energy saving
SEt_ES
4.4.4
Compressor parameters
PARAMETER
CODE
dAS
Minimum `On' time.
Minimum time between two compressor
dES
switch-ons.
AbCI
Compressor hour counter 1
4.4.5
General parameters
PARAMETER
CODE
CPt
precision control enable
4.4.6
B1, B2, B3 sensor parameters
PARAMETER
CODE
High temperature alarm (water)
HA1
Low temperature alarm (water)
LA1
High temperature alarm (evaporator)
HA2
Low temperature alarm (evaporator)
LA2
High temperature alarm (ambient)
HA3
Low temperature alarm (ambient)
LA3
English

4.5 Change parameters

Parameter (SEt / dIFI/ dEF )
4.5.1
TYPE
DEFAULT
Fig.2
OFF
D
20.0
D
esc
set
68.0
PAr
TYPE
DEFAULT
2
F
set
F
5
0
D
P_nA
TYPE
DEFAULT
OFF
U
TYPE
DEFAULT
60
set
D
140
-20
U
-4
60
U
140
3
U
5.4
CF30
60
U
140
-20
4.5.2
Water temperature setting (see fi g.1/2)
U
-4
1. Turn the main swicth (QS) to "ON" and wait for the "OFF" visu-
alization.
2. Press the buttons "
type "D" .
3. Select the parameter "PAr"using "
press the button "
4. Select the parameter "tEr"using "
press the button "
5. Select the parameter "SEt"using "
press the button "
6. Change the value using "
tEr
CnP
PbI
r9E
set
set
set
HA1
Ar9
set
C1H2
C1H
SEt
diFI
CF31
CF32
dEF
esc
set
" "
" together to enter on the parameter
"and "
" buttons and
set
" to enter.
"and "
" buttons and
set
" to enter.
"and "
" buttons and
set
" to enter.
"and "
" buttons and press the but-
ICEP007-024 (60Hz)
set
ton "
" to confi rm and exit.
esc
7. Press the button "
" three times to exit.
4.5.3
Diff erential setting (see fi g.1/2)
1.Turn the main swicth (QS) to "ON" and wait for the "OFF" visuali-
zation.
esc
set
2.Press the buttons "
" "
" together to enter on the parameter
type "D"
3.Select the parameter "PAr"using "
"and "
set
press the button "
" to enter.
4. Select the parameter "tEr"using "
"and "
set
press the button "
" to enter.
5. Select the parameter "dIFI"using "
set
press the button "
" to enter.
6. Change the value using "
"and "
" buttons and press the but-
set
ton "
" to confi rm and exit.
esc
7. Press the button "
" three times to exit.
4.5.4
Restore default parameters (see fi g.1/2)
1.Turn the main swicth (QS) to "ON" and wait for the "OFF" visuali-
zation.
esc
set
2.Press the buttons "
" "
" together to enter on the parameter
type "D"
3.Select the parameter "PAr"using "
"and "
set
press the button "
" to enter.
4. Select the parameter "P_nA"using "
set
press the button "
" to enter.
5. Select the parameter "dEF"using "
set
press the button "
" to enter.
6. Change the value "OFF" to "On" using "
set
and press the button "
" to confi rm and exit.
esc
7. Press the button "
" three times to exit.
" buttons and
" buttons and
"and "
" buttons and
" buttons and
"and "
" buttons and
"and "
" buttons and
"and "
" buttons
5 / 8

Publicité

Table des Matières
loading

Table des Matières