4.4.2

Temperature control

PARAMETER
CODE
Temperature control set point
SEt
Temperature control set point
SEt
" CPt= On"
Temperature control differential
dIFI
(NOT visible with code " CPt=
On")
4.4.3
Energy saving temperature control
PARAMETER
CODE
ESE
energy saving enable
Set energy saving
SEt_ES
4.4.4
Compressor parameters
PARAMETER
CODE
dAS
Minimum `On' time.
Minimum time between two com-
dES
pressor switch-ons.
AbCI
Compressor hour counter 1
4.4.5
B1, B2 sensor parameters
PARAMETER
CODE
High temperature alarm (water)
HA1
Low temperature alarm (water)
LA1
High temperature alarm
HA2
(evaporator)
Low temperature alarm (evapo-
LA2
rator)
English

4.5 Change parameters

Parameter (SEt / dIFI/ dEF )
4.5.1
TYPE
DEFAULT
Fig.2
--
D
--
esc
set
20.0
D
68.0
PAr
4
set
D
7.2
TYPE
DEFAULT
P_nA
OFF
D
20.0
D
68.0
TYPE
DEFAULT
set
2
F
F
5
0
D
TYPE
DEFAULT
CF30
60
D
140
-20
U
4.5.2
Water temperature setting (see fi g.1/2)
-4
1. Turn the main swicth (QS) to "ON" and wait for the "OFF" visualiza-
60
tion.
U
140
2. Press the buttons "
type "D" .
3
U
37.4
3. Select the parameter "PAr"using "
press the button "
4. Select the parameter "tEr"using "
press the button "
5. Select the parameter "SEt"using "
press the button "
6. Change the value using "
set
ton "
" to confi rm and exit.
tEr
CnP
PbI
r9E
set
set
set
HA1
Ar9
set
C1H2
C1H
diFI
SEt
CF31
CF32
dEF
esc
set
" "
" together to enter on the parameter
"and "
" buttons and
set
" to enter.
"and "
" buttons and
set
" to enter.
"and "
" buttons and
set
" to enter.
"and "
" buttons and press the but-
ICEP002 (60Hz)
esc
7. Press the button "
" three times to exit.
4.5.3
Differential setting (see fi g.1/2)
1.Turn the main swicth (QS) to "ON" and wait for the "OFF" visualiza-
tion.
esc
set
2.Press the buttons "
" "
" together to enter on the parameter
type "D"
3.Select the parameter "PAr"using "
"and "
set
press the button "
" to enter.
4. Select the parameter "tEr"using "
"and "
set
press the button "
" to enter.
5. Select the parameter "dIFI"using "
set
press the button "
" to enter.
6. Change the value using "
"and "
" buttons and press the but-
set
ton "
" to confi rm and exit.
esc
7. Press the button "
" three times to exit.
4.5.4
Restore default parameters (see fi g.1/2)
1.Turn the main swicth (QS) to "ON" and wait for the "OFF" visualiza-
tion.
esc
set
2.Press the buttons "
" "
" together to enter on the parameter
type "D"
3.Select the parameter "PAr"using "
"and "
set
press the button "
" to enter.
4. Select the parameter "P_nA"using "
set
press the button "
" to enter.
5. Select the parameter "dEF"using "
"and "
set
press the button "
" to enter.
6. Change the value "OFF" to "On" using "
set
and press the button "
" to confi rm and exit.
esc
7. Press the button "
" three times to exit.
" buttons and
" buttons and
"and "
" buttons and
" buttons and
"and "
" buttons and
" buttons and
"and "
" buttons
5 / 8

Publicité

Table des Matières
loading

Table des Matières