English
Please note:
•
Never assign double bus IDs.
Bus ID
S4/1
S4/2
1
OFF
OFF
2
OFF
OFF
3
OFF
OFF
4
OFF
ON
5
OFF
ON
6
OFF
ON
7
OFF
ON
8
ON
OFF
9
ON
OFF
10
ON
OFF
11
ON
OFF
12
OFF
ON
13
ON
ON
14
ON
ON
15
ON
ON
4.4
Switch S5
•
Switches S5/1, S5/2 and S5/3 are not needed on
any of the follower Wallboxes. Set these switches
to OFF.
•
Switch S5/2 is not required on the leader Wallbox.
Set the switch to OFF.
Configuration as leader and follower via
switch S5/4
S5/4
ON
Leader
OFF
Follower
Configuration of blocking function (in leader
Wallbox) via switch S5/3
•
The Wallbox has an input via which it can be
blocked by an external switching element
(key-operated switch or similar device; see
assembly instructions).
•
Use switch S5/3 to specify whether this blocking
is to affect only the leader Wallbox or all
Wallboxes.
S5/3
OFF
ON
4.5
Switch S6
The first and last devices on the RS485 bus must be
connected with a terminating resistor.
66
S4/3
S4/4
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
Only the leader Wallbox
is blocked.
All Wallboxes are
blocked.
Terminating resistor for last Wallbox
Use micro switch S6/2 to connect the built-in termi-
nating resistor on the last follower Wallbox. Switches
S6/1, S6/3 and S6/4 are not used. Set these switches
to OFF position.
S6/2
OFF
ON
Local load management
Leader
Follower1 Follower2
S6/2
Terminating resistor for leader Wallbox
Use micro switch S6/2 to connect the built-in termi-
nating resistor on the leader Wallbox. Switches S6/1,
S6/3 and S6/4 are not used. Set these switches to
OFF position.
External load management
Leader Follower1 Follower2
120 Ohm
HEMS terminating resistor
When using an external control unit, terminate
the bus line with a 120 Ohm resistor. Observe the
specifications from the manufacturer of the external
control system here.
5.
Bus protocol
(external load management)
The Modbus RTU protocol is used for communi-
cation between the external control system and
the Wallboxes. Each Wallbox is ready to receive a
Modbus command only after more than 10 seconds
have elapsed since Power On. If the corresponding
Wallbox is in standby mode, it cannot be addressed
via Modbus.
Bus termination inactive
Bus termination active
Follower3 Follower4
RS485
Follower3 Follower4 Follower5
RS485
S6/2
S6/2