Displaying faults are available as follows:
A complete listing of the faults can be found in TABLE 6: Fault Code Index.
The system parameters for setting minimum allowable cooling set point, maximum allowable heating set point and temperature display units can be adjusted
as follows:
TWO-SPEED PUMP: In a few cases the flow from a two-speed pump is below the minimum required to operate the water flow switch on the heater. In these
cases the pump must be run at high speed to operate the heater. If the pump and piping arrangement are such that the required minimum flow cannot be
obtained, do not attempt to operate the heater. Correct the installation.
NOTICE - Heater installation, checkout, and start-up should now be completed. BE SURE to leave this manual with the pool owner.
PERIODIC INSPECTION: The heater is designed and built for long performance life when installed and operated according to the manufacturer's directions.
Regular inspection by qualified service personnel is recommended to keep the heater working properly. The following inspection points are suggested to help
maximize heater life.
1.
Periodically check the fan discharge area. The fan discharge must never be obstructed in any way and minimum clearances must be observed.
Remember that shrubs grow and in time may obstruct
2.
Keep the entire pool heater area clean and free of all debris, corrosive materials, and other flammable vapors and liquids. Remove any leaves or
paper from around the heater.
3.
Do not store chlorine, other pool chemicals, or other corrosives in the vicinity of the heater.
4.
Do not use the heater if any part has been under water. Contact a qualified service technician to inspect the entire heater and replace any part of
the control system that was under water. If heater has been totally submerged in water it must be removed and the entire heater must be replaced.
5.
An inspection program is a good preventative maintenance measure. Keep this manual in a safe place for future reference for yourself as well
as for a service technician to consult when inspecting or servicing the heater. Additional inspection procedures to be performed by a qualified
service technician.
17
Press "Fault"
Press
"Parameter"
Enter the password "22" and press "OK"
Press the circular
touch button to
save entry
Maintenance & Service
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Press "
"
to Page Forward
Press "
"
to Page Back
Select "Parameters"

Publicité

Table des Matières
loading