connections are made inside the heat pump electrical compartment. Minimum wire size to be selected per NEC based on unit MCA.
3.
Electric disconnect switch that will interrupt all power to the unit. This switch MUST be within line of sight of the heat pump
4.
Do not install in a location where growing shrubs may in time obstruct a heater's air flow areas (sides or top).
5.
Do not install the heater where water spray from ground level can contact the heater. The water could damage coil or reach the controls causing
electrical damage.
6.
Do not install under a deck.
7.
Do not install within 24in of any outdoor HVAC equipment.
8.
Do not install where water may run-off a roof into the heater. A gutter may be needed to protect the heater.
CAUTION
- Make sure the heat pump is not located where large amounts of water may run-off from the roof into the unit. Sharp sloping roofs
without gutters will allow massive amounts of rainwater, mixed with debris from the roof to be forced through the unit. Failure to follow the instruc-
tions may result in property damage and a voided warranty.
1.
See Table 3 and Figure 3 for clearances.
2.
If the heat pump is to be installed below a vertical overhang such as shown in Figure
3, the unit must have a minimum of 72in. [1.8m] of clearance from the top of the
heat pump to the bottom of the cover or overhang.
3.
Install the heat pump a minimum of 60in. [1.5m] from the inside wall of the pool, spa,
solid fence, or permanent barrier. Canadian installations require a minimum of 120 in.
[3m] of clearance from pool water.
Figure 3: Outdoor Minimum Clearances
EQUIPMENT PAD: Place the heat pump on a level surface such as concrete or a fabricated slab (pad). This allows proper drainage of condensation and rain-
water from the base of the unit. If possible, the pad should be placed at the same level or slightly higher than the filter system equipment pad.
FLOORING: This heater may be installed on either non-combustible flooring or combustible flooring that does not reduce the bottom clearance of the heater.
Ultralite™ or equivalent concrete-over-foam HVAC pads are acceptable.
DRAINAGE AND CONDENSATION: Condensation will be produced by the evaporator coil when the unit is heating water and drain at a steady rate, usually three
to five gallons per hour, depending upon ambient air temperature and humidity. The more humid the conditions, the more condensation will be produced. Use
the supplied condensate drain to route the condensate away from the unit and dispose appropriately. It is easy to mistake the condensation for a water leak
inside the unit. A way to verify that the water is condensation is to shut off the unit and keep the pool pump running. If the water stops running out of the base
pan, it is condensation collecting around the unit. A quicker way is to check the water for CHLORINE. If there is no chlorine present in the water around the
unit, then it's condensation.
9
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Table 3: Installation Required Clearances
Heat Pump Panel
Outdoor Clearance
Top
Front (control)
Rest of Perimeter
Unobstructed
24-36
24