Fault code
CN017: Cal: signal
weak
CN018: Cal: Colli-
sion
CN038: Battery
CN099: Recov escape
58
All manuals and user guides at all-guides.com
Cause
Fault during the calibration:
Loop signal too weak
No loop signal
The boundary cable is
faulty.
Fault during the calibration:
The appliance has
bumped into an obstacle.
The rechargeable battery is
flat:
Loop of the boundary
cable is too long, too
many islands.
When charging, no con-
tact to the charging con-
tacts
Obstacles close to the
base station
The appliance has got
stuck.
The appliance does not
find the base station.
The rechargeable battery
is depleted.
The charging electronics
are faulty.
Automatic fault rectification
not possible
Help in case of malfunction
Remedy
Place the appliance at the pre-
scribed calibrating position; align
precisely at right angles.
Check the power source of the base
station. Disconnect and reconnect
the transformer.
Check the boundary cable for dam-
age.
Remove the obstacle.
Correct the location of the boundary
cable.
Clean the charging contacts.
Place the appliance in the base sta-
tion and check that the charging
contacts make contact.
Have the charging contacts checked
and replaced by a service centre of
the manufacturer.
Remove the obstacles.
Place the appliance on the free, desig-
nated grass surface.
Check the boundary cable for dam-
age.
Have the boundary cable repaired
by a service centre of the manufac-
turer.
Have the rechargeable battery replaced
by a service centre of the manufacturer.
Have the charging electronics checked
by a service centre of the manufacturer.
Manually acknowledge the malfunc-
tion message.
If the fault reoccurs: Have the appli-
ance checked by a service centre of
the manufacturer.
SRE2600X