Télécharger Imprimer la page

Assa Abloy JPM Push Control 930101 Notice De Pose page 6

Publicité

Les langues disponibles

Les langues disponibles

NOTICE DE POSE PUSH CONTROL 2 POINT
BLOCAGE, BLOCAGE+ DOGGING ET DOGGING
INSTALLATION INSTUCTION PUSH CONTROL SERIES FOR 2 RIM POINT
BLOCKING, BLOCKING + DOGGING AND DOGGING
3
ADJUSTMENT OF THE PANIC EXIT DEVICE (Length A•B)
For the active regulation, it is compulsory that the active part of the
bar covers at least 60 % of the door width. For Models 900, minimal
length 635mm, For Models 1200 mm minimal length 820 mm
Measure the distance between axis A and axis B
Cut the Panic Exit Device between A and B distance keeping the
bar in a depressed position.
You can't cut te panic exit device between the heat and the
marque mini cut
Take tare to cut square and without remaining particles,
eliminate the filings (fig 2 & 3)
4
INSTALLATION OF THE FOLLOWER (fig 4)
Only in case of a use with an outside trim EN2000 series.
Position of the follower
Position of the fixing plate
Insert and block the 2 screws M3x6 self-tapping screws
Check that the push bar works correctly
5
INSTALLATION OF THE MAGNETIC CONTACT FOR DOOR POSITION and
INSTALLATION OF THE CONNECTORS
IMPORTANT
The A space between the magnet and the detector must not exceed 10mm
Never bang on the detector to insert it in the drilling because it is "fragile".
the drill for the magnet and the detector must be precise enough (Ø 7,6 mm) to
allow correct insulation, if it is necessary, fix them with a glue adapted to
Mark and drill the detector hole, the magnet and wires passage position as indicated
below.
In case of a metallic frame, add the insulator for the magnet and the detector(Ø 11
mm).
Plug the two wires of the detector on the head circuit as indicated.
After cutting the bar at the right leaf dimension, check that no metallic particles are
remaining.
Pull out the nylon collar
until approaching the
connectors support at the end of
the bar.
6
FIXING (fig 5)
After having marked and drilled the necessary holes (chapter 1
Preparation of the door)
Screw the end bracket on the door by the mean of H5 screws without
blocking.
drill the wire passage (see additional instructions and template B)
Remove the front cover
Slide the back part of the panic exit system on its support.
Screw the front chassis and the outside trim on the door thanks to
the screws: H3 for standard doors -
Block the H5 screws of the rear bracket
in the chassis as indicated
NO1-705 Ind D
Fig 4
6 / 8

Publicité

loading

Ce manuel est également adapté pour:

Jpm push control 930111Jpm push control 930 411Jpm push control 930 310Jpm push control 940101Jpm push control 940111Jpm push control 940 411 ... Afficher tout