NOTICE DE POSE PUSH CONTROL 2 POINT
BLOCAGE, BLOCAGE+ DOGGING ET DOGGING
INSTALLATION INSTUCTION PUSH CONTROL SERIES FOR 2 RIM POINT
BLOCKING, BLOCKING + DOGGING AND DOGGING
The Exit is locked permanently and
Blocking and
Blocking detections
cannot be unlocked that par : The
detection fires (D.I. priority in all
cas) Un system CMSI UGCIS +
CLICK The broken glass box
Blocking and
situated next to the door
Dogging
Dogging (Motorised)
Exit is always free mecanic
Dogging Feature
Enables access control through motorization of the exit bar, retracting the latch bolt for free access. You have two options available within the dogging function
latching on/off (holdback timed) and momentary (holdback delayed).
Momentary (holdback delayed)
Retracts exit bar and latch bolt to enable free access for a number of seconds (2 -20 sec adjustable) then resets the exit bar and latch bolt to the normal position. If
bar was blocked before being dogged, bar is returned to the blocked state. Activation can be as simple as a momentary key switch through to a access control
system or a card reader.
Latching (holdback timed)
Allows the exit bar and latch bolt to be retracted for extended periods of time. Activation can be achieved by an external electronic time clock or via key switch or
access control panel.
1
PREPARATION OF THE DOOR (fig.1)
1Draw a horizontal axis 1035mm from finished floor, on interior side of door and frame (fig 1)
Draw a vertical axis 45mm from the edge of the frame (in order to permit the door free passage)
1Place A2 bis template on the door (on opening side) or A Axis
Mark and drill the door as indicated
H3 for standard doors
Cut out the B template for the end bracket and place it on the door in support on the frame (hinge
side)
Mark on the door the H5 points and the position of the B axis (23 mm minimum from the edge frame)
Measure the distance between A and B
Cut out the latch templates
Choose the right template according to the frame type and position it at the top of the vertical A
axis (fig 7 & 8 page 7)
D1 Template for overlapping doors – Fold up the template and place it in support on the frame
D2 template for flushed doors – Position the template on the top of the door
Draw and pre-drill as indicated (H1,H2, H8 and H9 points) (Fig 9 page 7)
Cut out and fold up the E template for the bottom latch and striker – Position the template to the
finished floor.
Draw and pre-drill as indicated H1,H2, H8 and H9 points (Fig 6 page 7)
Screw the rod cover retainers clips (fig 1, mark Clip 1 and 2)
2
According to you need magnet and reed switch see INSTRUCTION N01-814
Rim lead cover Option FM2412
JPM SAS
An ASSA ABLOY Group company
Versions 2 points
1 top, 1 bottom
Blocking NF S61-937 Fiche XIV
Blocking detection NF S61-937 Fiche XIV
BlocKing + Dogging + Détections NF S61-937 Fiche XIV
Dogging
EXIT
The entrance(entry) is possible by using handle
équiped outside EN3000 ' one ½ cylinder
The push control must be connected with an
Access control to allow the entrance(entry) to the
site (access unitarian or delayed by a clock for
example.) or by using handle équiped outside
EN3000 ' one ½ cylinder
Mortise lead cover option FM2500
NO1-705 Ind D
Recoupable de
ENTRANCE
Magnet reed switch deliver it, except 930101 940101
5 / 8
Recoupable de
838 à 635
1141 à 820
930101
940101
930111
940111
930 411
940 411
930 310
940 310