Capacitive uniaxial inclination sensor with Modbus interface
BSI R11A0-XXR-CXP360-S75G
Read out values (input register)
The actual values are in the input registers which are read
only (see register table).
The function code for reading applies to all input registers.
Slave ID Function
Address Quantity Checksum
code
1 byte
04
0000
Read
Read out inclination in the range of 360° (input register)
With the "Inclination" parameter, the inclination is read out
in the range of 0° to 359.99° with clockwise direction of
rotation (cw) in the 0 register.
Read
Slave ID Function
Address Quantity Checksum
code
1 byte
04
Read
Read out inclination in a different range (input register)
With the "Inclination with indicator options" parameter, the
tilt angle is read out in the changed "Indicator area" (regis-
ter 136) and with changed direction of rotation (register
135) in registers 17 or 18.
Read
Slave ID Function
Address Quantity Checksum
code
1 byte
04
Read
Read out sensor temperature (input register)
With the "Sensor temperature" parameter, the current
temperature of the sensor in register 10 is read out.
Slave ID Function
Address Quantity Checksum
code
1 byte
04
Read
6
English
Read
0x0001
2 bytes
0
0x0001
2 bytes
17
0x0002
2 bytes
or
18
Read
10
0x0001
2 bytes
Maintenance
The device is maintenance-free. The housing can be
cleaned as needed using a damp cloth and non-corrosive
cleaning solution when the device is switched off.
Decommissioning
Always uninstall the device in a deenergized state.
Disposal
The device must be disposed of according to European
Directives 2002/96/EC and 2003/108/EC (Waste Electrical
and Electronic Equipment). Old devices should be dis-
posed of separately from domestic waste!